![Denso GT20Q-SB User Manual Download Page 41](http://html1.mh-extra.com/html/denso/gt20q-sb/gt20q-sb_user-manual_2483241041.webp)
28
Example: Scanned data: “(01)94901234567894(11)030808(13)030810(17)040208(17)040305” Header: STX,
Terminator: ETX, Scanner ID: Prohibited, Code mark: Disabled, The number of digits: Disabled, Prefix/Suffix
transmission: Not specified, BCC transmission: Disabled
Parameters
Specified
AI
Delimiters
Output data
Transmit data
regardless of the
results:
Disabled
01,11,17
Comma
[STX]94901234567894,030808,040208[ETX]
17,11
[STX]040208,030808[ETX]
17,17
[STX]040208,040305[ETX]
12
Error
01,12
Error
01,01
Error
Transmit data
regardless of the
results:
Enabled
01,11,17
[STX]94901234567894,030808,040208[ETX]
17,11
[STX]040208,030808[ETX]
17,17
[STX]040208,040305[ETX]
12
[STX]019490123456789411030808130308101704020817040305[ETX]
01,12
01,01
Note
: The edited output data is output in the AI-specified set order.
Note
: Data is output in the order in which data is scanned if multiple identical AI-specified data exists in the
scanned data.
Note
: When “Transmit data regardless of the results” is disabled, an error will occur if the scanned data contains
none of the data specified in the AI extract or there are insufficient digits.