97
Settings
Parameters
Default
Refer to
Data string verification start position
001-999 digits
ASCII characters specified
1
Data string verification digits
(without preset master registration)
01-99 digits
ASCII characters specified
99
Data block verification block position
01-99 digits
ASCII characters specified
1
Verification result transmission:
OK result
Transfer disabled
Code data transmitted
“OK” transmitted
Verification result transmission: NG
result
Transfer disabled
Code data transmitted
“NG” transmitted
Reverification attempt after NG
judgment
(During 2-point verification only)
Enabled
Disabled
Verification range
Code type + code data
Code data only
Applicable codes for data editing
Specified from codes
Any code
(Note 1)
Data editing error processing
Transmit data regardless of the
results
Transmit data when successful
“Data Extraction Mode” during data
editing
Data string extraction
Data block extraction
AI mode
“Data string extraction” start position
First character
Last character
Specified position
“Data string extraction” end position
Last character
Specified no. of digits
Specified position
“Data string extraction” start digit
0001-9999 digits
ASCII characters specified
1
“Data string extraction” end digit
0001-9999 digits
ASCII characters specified
9999
: Only available via configuration software.
Note 1: When “Any code” is selected, all code data is edited.