50
9.4 Communication Format
Select the data communication format from the following two options.
Header
Scanner
ID
Code
mark
Prefix
Number of digits
Code data
Suffix
Terminator
BCC
n1 n2 n3 n4
Header
Scanner
ID
Prefix
Code
mark
Number of digits
Code data
Suffix
Terminator
BCC
n1 n2 n3 n4
Each item is described as follows:
(1) Header and Terminator
Select from the following options.
SPP Profile
Header:
None (default), STX, or user selection
Terminator:
CR (default), none, LF, CR/LF, ETX, or user selection
HID Profile
Header:
None (default), TAB, ESC, or ENTER, etc.
Terminator:
None, TAB, ESC, or ENTER (default), etc.
Refer to
for details.
(2) Scanner ID
Transfer is conducted using the unique 6-digit scanner ID (serial number) set at factory shipment.
(3) Prefix/Suffix
A prefix/suffix of up to 8 bytes can be set from a combination of any ASCII characters (00h to FFh) using the configuration
software (ScannerSetting_2D). (Default: None)
(4) BCC
The XOR (exclusive or) is made for each bit that comes after the header up to the terminator, and is transmitted as binary code
in single bytes. You can select whether or not to transmit the BCC. BCC is not transferred if there is no header, or the scanner
is set to HID profile.