2D code Handy Scanner
GT20Q-SB
User’s Manual
Page 1: ...2D code Handy Scanner GT20Q SB User s Manual ...
Page 2: ...t is strictly prohibited QR Code iQR Code SQRC and QBdirect are registered trademarks of DENSO WAVE INCORPORATED iPad and iPhone are registered trademarks of Apple Inc Windows is a registered trademark of Microsoft Corporation in the United States and other countries The Bluetooth wordmark is a registered trademark of Bluetooth SIG Inc Company names and products are generally the trademark or regi...
Page 3: ...canning Using the Trigger Switch 11 5 2 Scanning Using Software Control 13 5 3 Scanning through Automatic Label Recognition 14 Chapter 6 Magic Key 15 Chapter 7 Scanning Function 18 7 1 Data Verification Mode 18 7 1 1 Data Verification Scanning Procedures 18 7 1 2 Designating Targets for Data Verification 20 7 1 3 Verification Result Output 21 7 2 Data Edit Mode 22 7 2 1 Data Extraction Mode 22 7 2...
Page 4: ...2 10 2 Rechargeable Battery Cartridge Replacement Method 74 10 3 Recycling the Rechargeable Battery Cartridge 76 Chapter 11 Image Capture Function 77 11 1 Function Outline 77 11 2 Specifications 77 Chapter 12 Settings Overview and Factory Settings 80 Chapter 13 QR coded Parameter Menu 99 13 1 Setting Methods via the QR coded Parameter Menu 99 13 2 QR coded Parameter Menu 100 Chapter 14 QR Coded Pa...
Page 5: ...or any patent or other intellectual property right infringement s or violation s which arise from i the use of DENSO WAVE s product s in connection or in combination with other component s product s data processing system s or equipment or software not supplied from DENSO WAVE ii the use of DENSO WAVE s products in a manner for which the same were not intended nor designed or iii any modification ...
Page 6: ...death if the instructions are not followed correctly WARNING Alerts you to those conditions which could cause serious bodily injury or death if the instructions are not followed correctly CAUTION Alerts you to those conditions that could cause minor bodily injury or substantial property damage if the instructions are not followed correctly Meaning of Symbols A triangle with a picture inside alerts...
Page 7: ...r high temperature locations Never charge or use the rechargeable battery cartridge where any inflammable gases may be emitted Do not stick a needle into the rechargeable battery cartridge hammer it or tread on it Do not let the rechargeable battery cartridge undergo any shock or impact or throw it at something hard Do not use a rechargeable battery cartridge that is notably deformed scratched or ...
Page 8: ...emove the rechargeable battery cartridge from the scanner and contact your nearest dealer Failure to do so could cause fire or electrical shock If the device ceases to operate or its housing is broken due to being dropped or receiving any other strong impact immediately remove the rechargeable battery cartridge from the scanner and contact your nearest dealer Failure to do so could cause fire or e...
Page 9: ...or wrap in a cloth or blanket Doing so could cause the unit to heat up inside deforming its housing resulting in a fire Always use the scanner in a well ventilated area Do not insert or drop foreign materials such as metals or anything inflammable through the openings into the scanner Doing so could result in a fire or electrical shock Never scratch or modify the scanner Doing so could damage the ...
Page 10: ...ing care and maintenance for safety remove the rechargeable battery cartridge from the scanner Failure to do so could result in an electrical shock Never drop the scanner The scanner housing may break causing injuries Remove the rechargeable battery cartridge from the scanner and contact your nearest dealer Failure to do so could result in smoke or fire ...
Page 11: ... AD2 series For communications adapter For RS 232C interface use a communications adapter in conjunction with the battery charger 5 RS 232C interface cable for battery charger incorporation CBBA RS2000 9 1 For USB interfaces USB keyboard or USB COM 5 USB interface cable CBBA US2000 4 When communicating directly with Bluetooth equipped devices when not using a communications adapter BA11 RKU BA20 1...
Page 12: ...ion may not be possible when near these devices Electromagnetic noise from computers refrigerators or other home appliances may make communication impossible when nearby Communication may not be possible in the following locations Locations near metal or in which there is a lot of metallic powder Rooms enclosed by metallic walls Locations which receive strong vibrations Although the general possib...
Page 13: ...plate doing so will scratch or damage it Blow the particles away with an airbrush or a soft brush Proper Care of the Scanner Body Wipe any dirt from the scanner body with a dry soft cloth CAUTION Never use substances such as benzine or alcohol as this may cause the housing to be marred or paint to peel off If excessively dirty wipe with a soft cloth that has been soaked in soapy water always use n...
Page 14: ...ate switching mode Continuous reading mode 1 Continuous reading mode 2 Auto sensing mode Auto stand mode Factory settings Set to auto off mode Refer to Chapter 5 for details Lower housing Open the lower housing when replacing the rechargeable battery cartridge Refer to Section 10 2 for details on replacing the rechargeable battery cartridge Magic key Operates as an auxiliary key for scanning or da...
Page 15: ...ns where there is a possibility that Bluetooth radio waves 2400 MHz 2483 5 MHz 2 5 mW max may have an effect disable the Bluetooth wireless communication function of this scanner To disable the Bluetooth wireless communication function of this scanner read the End operation QR code in Section 13 2 following the procedure in Section 13 1 Note When in the default factory setting or End operation has...
Page 16: ...et as slave QR code in Section 13 2 following the procedure in Section 13 1 to set it as a slave device 2 Set a usage profile The profile can be set up in configuration software ScannerSetting_2D Factory settings Set to SPP profile 3 When settings have been completed and the beeper sounds three times pull the trigger switch The scanner will wait for a connection from a master device for approximat...
Page 17: ...setting the confirmed Bluetooth address When using commercial code creation software create a code in the below formats Code type Data format QR Code Model 1 2 ADDRXXXXXXXXXXXX Code 128 Code Set A ADDRXXXXXXXXXXXX Note Specify the Bluetooth address hexadecimal in the XXXXXXXXXXXX portion Example Bluetooth address 000AF1234567 3 Set a usage profile The profile can be set up in configuration softwar...
Page 18: ...ide the software keyboard by pulling the trigger switch two times within a short amount of time This function is limited to when iPhone iPad has been selected as the connecting device This function can be enabled and disabled using the configuration software ScannerSetting_2D 2 3 Disconnecting Bluetooth wireless communication Press and hold the magic key for at least 2 seconds or read the Disconne...
Page 19: ... Bluetooth disconnect scanning Cancels Bluetooth disconnect scanning Enables code scanning when Bluetooth wireless communication has been connected As the Bluetooth wireless communication function is enabled data can be transferred to and from the host computer Note When Bluetooth disconnect scanning is enabled it will remain enabled even if End operation or Start operation QR coded parameter menu...
Page 20: ...he trigger switch 2 5 Scanner Bluetooth wireless communication connection status The user can confirm the Bluetooth wireless communication connection status of the scanner using the scanner indicator LED and the timing of the beeper When the trigger switch is pulled and held down Indicator LED status Beeper Scanner status Flashes in red fixed period Does not sound A scan was performed while the sc...
Page 21: ...anned Note The scannable range is smaller than the area indicated by the markers When the scanning distance is 7 5 cm the scannable range is approximately 6 4 cm Note Unless multi line barcode scanning is enabled or the split QR Code scanning mode is set to batch edit mode do not attempt to place more than one code within the scannable range If two codes are in the scannable range simultaneously t...
Page 22: ...en the scanner has entered the Ready state in alternate switching mode it will enter Sleep state in order to reduce power consumption The scanner will not enter the Sleep state when in continuous reading mode 1 or 2 or auto sensing mode The scanner will enter the Sleep state after 30 s in Normal consumption mode and will enter Sleep state immediately in Low consumption mode default Normal consumpt...
Page 23: ...ommend that the scanner be set as the master device It is possible to generate a batch setting QR Code with the configuration software and set parameters by reading it with the scanner Note Because Bluetooth wireless communication is disconnected when the scanner is set using the configuration software and batch setting QR code reconnection is required once settings have been configured successful...
Page 24: ...omatically returns to the Ready state when scanning is successfully completed or after approximately five seconds have elapsed with the trigger switch pulled If the trigger switch is released before five seconds have elapsed the scanner returns to the Ready state One shot The scanner only remains in the Active state for the one shot setting duration once the trigger switch is pulled The one shot s...
Page 25: ... LON command Using the configuration software ScannerSetting_2D the user can select whether to send an ERROR command to the host unit when the scanner enters the Ready state after failing to complete the scan while in Active state Note The scanner will enter the auto off mode regardless of the trigger switch settings while parameters are being set in the QR coded parameter menu Note Trigger switch...
Page 26: ...s Content Trigger switch operation mode Auto off mode Momentary switching mode Reverse type Momentary switching mode Alternate switching mode Continuous reading mode 1 Continuous reading mode 2 R READON LON Activation commands When these commands are received the illumination light comes on and the scanner enters the Active state Z READOFF LOFF Ready commands When these commands are received the i...
Page 27: ...cted in configuration software ScannerSetting_2D Manual If the trigger switch is pulled three times within approximately one second while the scanner is operating in auto off mode the scanner switches to auto sensing mode Automatic The scanner automatically returns to the auto sensing mode when after switching to auto off Ready state the trigger switch is not pulled for longer than the time specif...
Page 28: ...figuration software ScannerSetting_2D every time the magic key is pressed 4 Scanning active ready switching function Toggles between Ready state and Active state every time the magic key is pressed when the trigger switch operation mode is in continuous reading mode 1 or 2 If the error message for scan failure is enabled the ERROR command is sent to the host when the scanner switches from the Acti...
Page 29: ...ction Master code registration Pressing the magic key for approximately two seconds when in data verification mode refer to Section 7 1 causes the indicator LED to illuminate in green indicating that the master code has been registered Codes read while the magic key is held down will become master codes Scan lock release Pressing the magic key releases the Ready state set by the scan lock function...
Page 30: ...master mode the scanner connects to the slave device in slave mode the scanner awaits a connection from the master device Host connection standby For first time connections regardless of whether the scanner is in master mode or slave mode the scanner automatically switches to slave mode and awaits a connection from the connecting device The Bluetooth wireless communication mode parameters are the ...
Page 31: ...registration is only available in the n point verification mode Register the code type and the portion of data to be verified using the configuration software ScannerSetting_2D Up to 99 digits of data can be registered The registered master data will be retained even after the scanner is turned off To clear the registered data use the configuration software ScannerSetting_2D and clear the master d...
Page 32: ...n registering the master data an error occurs if the data read does not meet the number of characters of the registered verification data such as when the number of digits is less than the specified verification starting position If an error occurs the scanner will return to the master data registration standby state Reverification attempt after NG judgment in 2 point verification 2 point verifica...
Page 33: ... the specified area Example Master data Verification start position Number of verification digits Scanned data for verification Verification result 345 3 3 00345 Match 345 3 3 00345678 Match 345 3 3 00346 Mismatch 345 3 3 0034 Mismatch 2 Data Block Verification The scanner compares the CSV formatted data block separated by commas with the registered master data and then outputs the result The veri...
Page 34: ... when the beeper indicator LED and vibrator are enabled Beeper Indicator LED Vibrator Vibration enabled for OK result Vibration enabled for NG result Verification matched Short beep Blue light Vibration Verification mismatched Long beep Red light Vibration 3 Scan Lock Release The scan lock is a function used to lock the scanner in the Ready state if a mismatch occurs Select using the configuration...
Page 35: ...arried out regardless of the code mark type setting Refer to Section 9 4 5 Note The scanner edits split QR or iQR Codes after all the split codes are completely scanned in the edit mode or batch edit mode The scanner edits split codes on an individual bases each time a split code is scanned in the non edit mode 7 2 1 Data Extraction Mode The scanner extracts a portion of the scanned data for outpu...
Page 36: ...ion and extraction end position values are as follows Parameters Parameters Value Code type Any code QR Code iQR Code PDF417 Data Matrix MaxiCode Aztec UPC A EAN 13 UPC E EAN 8 Code 128 GS1 128 Codabar NW 7 Code 39 Code 93 Interleaved 2 of 5 ITF Standard 2 of 5 STF GS1 DataBar GS1 Composite Transmit data regardless of the results Enabled Disabled When Transmit data regardless of the results is ena...
Page 37: ...ansmission Disabled Parameters Extraction start position Extraction end position Output data Code type QR Transmit data regardless of the results Disabled First character 3rd digit STX Q0003123 ETX Last character 3rd digit STX Q0003345 ETX 1st digit Last character STX Q000512345 ETX 1st digit 3 digit length STX Q0003123 ETX 2nd digit 4th digit STX Q0003234 ETX First character 6th digit Error Last ...
Page 38: ...ny code QR Code iQR Code PDF417 Data Matrix MaxiCode Aztec UPC A EAN 13 UPC E EAN 8 Code 128 GS1 128 Codabar NW 7 Code 39 Code 93 Interleaved 2 of 5 ITF Standard 2 of 5 STF GS1 DataBar GS1 Composite Transmit data regardless of the results Enabled Disabled When Transmit data regardless of the results is enabled the scanned data will be output without editing if data block extraction fails or a non ...
Page 39: ...6 7890 3 1 2 STX 456 ETX STX 1 ETX STX 2 3 ETX 1234567890 1 STX 1234567890 ETX 1 23 456 7890 2 5 STX ETX STX 7890 ETX 1 23 456 7890 5 Error 1 23 456 7890 4 5 Error 1234567890 1 2 Error Code type QR Transmit data regardless of the results Enabled 1 23 456 7890 5 STX 1 23 456 7890 ETX 1 23 456 7890 4 5 STX 1 23 456 7890 ETX 1234567890 1 2 STX 1234567890 ETX Code type PDF417 Transmit data regardless ...
Page 40: ... 030808 13 030810 Header STX Terminator ETX Scanner ID Prohibited Code mark Disabled The number of digits Disabled Prefix Suffix transmission Not specified BCC transmission Disabled Specified AI Output Data 01 11 13 STX 001494901234567894 ETX STX 0006030808 ETX STX 0006030810 ETX Comma The scanner outputs split strings delimited by commas No comma is added to the last item of split data A header a...
Page 41: ...305 ETX 12 Error 01 12 Error 01 01 Error Transmit data regardless of the results Enabled 01 11 17 STX 94901234567894 030808 040208 ETX 17 11 STX 040208 030808 ETX 17 17 STX 040208 040305 ETX 12 STX 019490123456789411030808130308101704020817040305 ETX 01 12 01 01 Note The edited output data is output in the AI specified set order Note Data is output in the order in which data is scanned if multiple...
Page 42: ...canned data Output data Transmit data regardless of the results Disabled 0194901234567894110308081303 081017040208 STX 01 94901234567894 11 030 808 13 030810 17 040208 ETX 0194901234567894110308081303 081061704020817040305 Error refer to the details below Transmit data regardless of the results Enabled 0194901234567894110308081303 081017040208 STX 01 94901234567894 11 030 808 13 030810 17 040208 E...
Page 43: ...n2 Variant Number 21 n2 an 20 Serial Number 22 n2 an 29 Application conforming to the definition of HIBCC Health Industry Business Communication Council 23n n3 n 19 Batch or Lot Number for transitional use 240 n3 an 30 Additional Product Identification Assigned by the Manufacturer 241 n3 an 30 Customer Part Number 250 n3 an 30 Secondary Serial Number 251 n3 an 30 Reference to Source Entity 252 n3 ...
Page 44: ...sion Meters Logistics Measures 334n n4 n6 Area Square meters symbol logic 335n n4 n6 Logistic volume Liters 336n n4 n6 Logistic volume Cubic meters 337n n4 n6 Kilograms Per Square Meter Pressure 340n n4 n6 Logistic weight Pounds 341n n4 n6 Length or first dimension Inches Logistics Measures 342n n4 n6 Length or first dimension Feet Logistics Measures 343n n4 n6 Length or first dimension Yards Logi...
Page 45: ...15 Amount Payable Single Monetary Area 391n n4 n3 n15 Amount Payable and ISO Currency Code 392n n4 n15 Amount Payable for a Variable Measure Trade Item Single Monetary Area 393n n4 n3 n15 Amount Payable for a Variable Measure Trade Item and ISO Currency Code 400 n3 an 30 Customer s Purchase Order Number 401 n3 an 30 Global Identification Number for Consignment GINC 402 n3 n17 Global Shipment Ident...
Page 46: ...th Three Digit ISO Country Code Second through ninth processing location 8001 n4 n14 Roll Products Width Length Core Diameter Direction Splices 8002 n4 an 20 Cellular Mobile Telephone Identifier 8003 n4 n14 an 16 Global Returnable Asset Identifier GRAI 8004 n4 an 30 Global Individual Asset Identifier GIAI 8005 n4 n6 Price per Unit of Measure 8006 n4 n14 n2 n2 Identification of the Components of a ...
Page 47: ...year and month only n indicates the data length n indicates the location of the decimal point a Alphabetic characters a3 Three alphabetic characters a 3 Up to three alphabetic characters n numerals n3 Three numerals n 3 Up to three numerals an Alphanumeric character an3 Three alphanumeric characters an 3 Up to three alphanumeric characters Note When the length of the specified AI is variable and t...
Page 48: ...MaxiCode Aztec UPC A EAN 13 UPC E EAN 8 Code 128 GS1 128 Codabar NW 7 Code 39 Code 93 Interleaved 2 of 5 ITF Standard 2 of 5 STF GS1 DataBar GS1 Composite Characters for conversion Converted characters Set a maximum of 16 ASCII characters 00h FFh Example Scanned code PDF417 Scanned data 12345678 Header STX Terminator ETX Scanner ID Prohibited Code mark Disabled The Number of Digits Disabled Prefix...
Page 49: ...eters Value Code type Any code QR Code iQR Code PDF417 Data Matrix MaxiCode Aztec UPC A EAN 13 UPC E EAN 8 Code 128 GS1 128 Codabar NW 7 Code 39 Code 93 Interleaved 2 of 5 ITF Standard 2 of 5 STF GS1 DataBar GS1 Composite Example Scanned code Code 128 Scanned data 1234567890 Header STX Terminator ETX Scanner ID Prohibited Code mark Disabled The Number of Digits 4 digit transmission enabled Prefix ...
Page 50: ...ainder calculation such as unit conversion 7 Data conversion substitution 8 Character string comparison 9 Control of the indicator LED beeper and vibrator Use the configuration software ScannerSetting_2D to create an ADF script Set up the ADF script on the scanner using the configuration software or by scanning a configuration QR Code created to set up the ADF script Refer to the ADF Script User s...
Page 51: ...he marker The code will not be scanned if there is no code under the intersection of the cross or if the scanner cannot detect the marker due to external light etc Also this mode is available only when marker illumination is enabled 7 5 Mirror Image Code Scanning The scanner can scan both standard and mirror image 2D codes Use the configuration software ScannerSetting_2D to enable or disable the m...
Page 52: ...puter each time an individual split code is scanned The beeper sounds twice when split code scanning commences scanning of the initial split code completes and three times when split code scanning is complete scanning of all codes is complete Note If the scanner scans a QR iQR code that is not split or a code other than a QR iQR code while operating in split code scanning mode split code scanning ...
Page 53: ...sion format refer to Section 9 4 The number of digits will be omitted for the UPC and EAN codes 2 Comma Data is output separated by commas in accordance with the specified data transmission format refer to Section 9 4 Only the code mark set for the first line is output and the number of digits includes commas The number of digits is not omitted for UPC and EAN codes in comma delimited formats Note...
Page 54: ... longer short beeps or when the software keyboard on off switching function has been used iPhone iPad connections only 2 short beeps The beeper emits a long beep when the code data scanned in data verification mode does not match the master data the stored data of a split QR Code scanned in edit mode exceeds 8KB a master code digit number error has occurred during master data registration a code o...
Page 55: ...nges take effect when the scanner scans a batch setting QR Code or when the parameter values are saved by a PW command refer to Appendix 2 2 Adjusting the Beeper Volume Use the QR coded parameter menu or configuration software ScannerSetting_2D to adjust the beeper volume to three levels high medium and low Each time the Beeper volume QR Code is read the beeper volume cycles as shown below The fin...
Page 56: ...e trigger switch control is deactivated or Bluetooth communication has been disconnected The indicator LED flashes in red when the scanner has received an abnormal control command the scanner has failed to edit read data the master data has not been registered successfully in data verification mode n point the code scanned in data verification mode does not match the master data a digit number err...
Page 57: ...r is in entry mode refer to control command E in Appendix 2 during master data registration and when master data registration has successfully completed when an error occurs during master data registration when scanned code data does not match when scan lock is enabled or when master data has not been registered successfully in data verification mode when a transfer has been successfully completed...
Page 58: ... reader mode is successfully released with the temporary barcode reader mode release function If NG vibration is enabled the scanner will vibrate when a digit number error has occurred during master data registration in data verification mode the code data scanned in data verification mode does not match the master data the stored data of a split QR Code scanned in edit mode exceeds 8KB the scanne...
Page 59: ...ker beam turns off When the trigger switch is in momentary switching mode Reverse type In Momentary switching mode reverse type the marker beam illuminates continuously when the trigger switch is released When the scanner is ready when the trigger switch is released in Momentary switching mode reverse type the marker beam illuminates continuously When the scanner is on standby when the trigger swi...
Page 60: ...llumination lights can be turned on or off When the illumination LEDs are on it is possible to activate an ECO mode which controls the brightness of the LEDs and reduces electrical consumption by 20 Factory settings Set to ECO mode When ECO mode is activated scanning distance is shortened in dark locations with ambient illumination of 500 Lx or less ...
Page 61: ... SPP which can connect to an Android device PC or other device equipped with a Bluetooth Specification Ver 2 1 EDR compatible Bluetooth module The user can select Non acknowledge mode ACK NAK mode or data packing data packetizing Non acknowledge mode default Scanned data is sent ACK NAK mode Scanned data is sent and then processed according to the response from the computer etc ACK Normal completi...
Page 62: ...uts it bytewise 80h to FFh data is not output with this setting Scanning operations are completed even though the data is not output Binary conversion Converts 00h to FFh data to binary format and outputs it bytewise Kanji conversion Converts 00h to FFh data to Shift JIS format and outputs it two bytes at a time If there is any data to which this Kanji conversion cannot be applied such data is con...
Page 63: ...ID Profile Header None default TAB ESC or ENTER etc Terminator None TAB ESC or ENTER default etc Refer to Chapter 12 for details 2 Scanner ID Transfer is conducted using the unique 6 digit scanner ID serial number set at factory shipment 3 Prefix Suffix A prefix suffix of up to 8 bytes can be set from a combination of any ASCII characters 00h to FFh using the configuration software ScannerSetting_...
Page 64: ...ation of any ASCII characters 00h to FEh for each of the following barcode types You can also select whether or not to transmit the code mark Default Transfer disabled Code Type Code mark Type1 Type2 Coupling Separating Coupling Separating 2D code QR code Q Q QR code Split mode Edit mode Q Q Batch edit mode Q Q Non edit mode S S Micro QR code Q Q SQRC Q Q iQR code G G iQR code Split mode Edit mode...
Page 65: ...With 5 digit add on Linear A F Add on None None EAN 8 Without add on B FF With 2 digit add on Linear B FF Add on None None With 5 digit add on Linear B FF Add on None None Interleaved 2 of 5 I I Standard 2 of 5 short H H Standard 2 of 5 normal H H Code 39 M M Code 39 Full ASCII M M Codabar NW 7 N N Code 128 K K GS1 128 W W Code 93 L L GS1 DataBar Note 1 R R ...
Page 66: ... add on Linear V A V F Add on None None None None With 5 digit add on Linear V A V F Add on None None None None CC A CC B None Y Note 2 None Y Note 2 UPC E CC A UPC E CC B UPC E Without add on V C V E With 2 digit add on Linear V C V E Add on None None None None With 5 digit add on Linear V C V E Add on None None None None CC A CC B None Y Note 2 None Y Note 2 EAN 8 CC A EAN 8 CC B EAN 8 Without a...
Page 67: ...rcode UPC A Without add on A X0 With 2 digit add on Linear A X3 X0 Add on None None X1 Note 2 With 5 digit add on Linear A X3 X0 Add on None None X2 Note 2 UPC E Without add on A X0 With 2 digit add on Linear A X3 X0 Add on None None X1 Note 2 With 5 digit add on Linear A X3 X0 Add on None None X2 Note 2 EAN 13 Without add on A E0 With 2 digit add on Linear A E3 E0 Add on None None E1 Note 2 With ...
Page 68: ... A CC B None X Note 2 e0 Note 2 EAN 13 CC A EAN 13 CC B EAN 13 Without add on T A E0 With 2 digit add on Linear T A E3 E0 Add on None None None E1 Note 2 With 5 digit add on Linear T A E3 E0 Add on None None None E2 Note 2 CC A CC B None X Note 2 e0 Note 2 UPC E CC A UPC E CC B UPC E Without add on T A X0 With 2 digit add on Linear T A X3 X0 Add on None None None X1 Note 2 With 5 digit add on Line...
Page 69: ...1st message character 2 FNC1 subsequent to the 1st character or digit pair Barcode Interleaved 2 of 5 0 Scanning enabled without a check digit 1 Scanning enabled with a check digit Check digit transmission enabled 3 Scanning enabled with a check digit Check digit transmission disabled Code 39 Code 39 Full ASCII 0 Scanning enabled without a check digit 1 Scanning enabled with a check digit Check di...
Page 70: ...ts scanned data and transmits it It does not transmit the code number number of splits or parity In non edit mode The scanner transmits the code number the number of splits parity and scanned code data The code number and number of splits are transmitted in single bytes in hexadecimal format Parity is transmitted in 2 bytes in the same format SQRC The scanned data is transmitted as is When Transmi...
Page 71: ...o GTIN format When conversion to GTIN format is disabled the following format applies With 2 digit add on 0 S X1 X2 X3 X4 X5 X6 X7 X8 X9 X10 C D X11 X12 With 5 digit add on 0 S X1 X2 X3 X4 X5 X6 X7 X8 X9 X10 C D X11 X12 X13 X14 X15 0 Padding character for adjustment of the data length S Number system character X11 15 Add on code data UPC E You can select whether or not to transmit the padding char...
Page 72: ...6 3 0 S X1 X2 X3 0 0 0 0 0 X4 X5 C D X7 X8 X9 X10 X11 X6 4 0 S X1 X2 X3 X4 0 0 0 0 0 X5 C D X7 X8 X9 X10 X11 X6 5 9 0 S X1 X2 X3 X4 X5 0 0 0 0 X6 C D X7 X8 X9 X10 X11 0 Padding character for adjustment of the data length S Number system character X7 11 Add on code data EAN 13 You can select whether or not to transmit the two prefix characters P1 and P2 and the check digit to the host Conversion to...
Page 73: ...ther or not to convert to GTIN format and EAN 13 Refer to Section 9 5 for details on enabling conversion to GTIN format When conversion to GTIN format is disabled the following format applies Conversion to EAN 13 disabled P1 P2 P3 X1 X2 X3 X4 C D Conversion to EAN 13 enabled 0 0 0 0 0 P1 P2 P3 X1 X2 X3 X4 C D Pn Prefix character With EAN 8 Add on If the scanner is set to Code mark type Type 4 and ...
Page 74: ...data is transmitted without the start stop codes and check digit GS1 DataBar The scanned data is transmitted as is For GS1 DataBar Expanded FNC1 the user can select between the following options disable transmission conversion to GS 1Dh and transmission user selection You can also select whether or not to convert to GTIN format Refer to Section 9 5 for details on enabling conversion to GTIN format...
Page 75: ...rk output mode Separating a code mark will be applied in front of the add on component and between the add on code data and 2D code data For details on the code mark applied refer to Section 9 4 5 GS1 128 Composite The scanned data is transmitted as is If the scanner is set to Code mark type Type 1 and Code mark output mode Separating a separator GS 1Dh and 2D code mark will be applied between the...
Page 76: ...entifier 01 and package indicator PI will be added at the start of the code before transmission if 14 digit code conversion is selected PI will be added at the start of the code However this will not be applied to output formats that can be specified in UPC A UPC E EAN 13 and EAN 8 UPC A Scanned data 0 S X1 X2 X3 X4 X5 X6 X7 X8 X9 X10 C D 0 Padding character for adjustment of the data length S Num...
Page 77: ...n PI 0 S X1 X2 X3 X4 X5 X6 X7 X8 X9 X10 C D X11 X12 X13 X14 X15 2 2 The check digit is recalculated and transmitted regardless of whether or not transmission is enabled UPC E Scanned data 0 X1 X2 X3 X4 X5 X6 C D 0 Padding character for adjustment of the data length Conversion to 16 digits the application identifier 01 and PI are added at the start of the code before transmission X6 0 2 0 1 PI 0 0 ...
Page 78: ...start of the code before transmission With 2 digit add on X6 0 2 PI 0 S X1 X2 X6 0 0 0 0 X3 X4 X5 C D X7 X8 2 X6 3 PI 0 S X1 X2 X3 0 0 0 0 0 X4 X5 C D X7 X8 2 X6 4 PI 0 S X1 X2 X3 X4 0 0 0 0 0 X5 C D X7 X8 2 X6 5 9 PI 0 S X1 X2 X3 X4 X5 0 0 0 0 X6 C D X7 X8 2 With 5 digit add on X6 0 2 PI 0 S X1 X2 X6 0 0 0 0 X3 X4 X5 C D X7 X8 X9 X10 X11 2 X6 3 PI 0 S X1 X2 X3 0 0 0 0 0 X4 X5 C D X7 X8 X9 X10 X11...
Page 79: ...at the start of the code before transmission With 2 digit add on PI P1 P2 P3 X1 X2 X3 X4 X5 X6 X7 X8 X9 C D X10 X11 2 With 5 digit add on PI P1 P2 P3 X1 X2 X3 X4 X5 X6 X7 X8 X9 C D X10 X11 X12 X13 X14 2 2 The check digit is recalculated and transmitted regardless of whether or not transmission is enabled EAN 8 Scanned data P1 P2 P3 X1 X2 X3 X4 C D Pn Prefix character Conversion to 16 digits the ap...
Page 80: ...ether or not transmission is enabled Conversion to 14 digits PI is added at the start of the code before transmission With 2 digit add on PI 0 0 0 0 0 P1 P2 X1 X2 X3 X4 C D X5 X6 2 With 5 digit add on PI 0 0 0 0 0 P1 P2 X1 X2 X3 X4 C D X5 X6 X7 X8 X9 2 2 The check digit is recalculated and transmitted regardless of whether or not transmission is enabled Interleaved 2 of 5 14 digits Scanned data X1...
Page 81: ...not transmitted X1 X2 X3 X4 X5 X6 X7 X8 X9 X10 X11 X12 C D 1 1 The check digit is recalculated and transmitted If code mark transmission is enabled in the scanner settings the EAN 13 code mark is transmitted Conversion to 14 digits the application identifier 01 is not transmitted PI X1 X2 X3 X4 X5 X6 X7 X8 X9 X10 X11 X12 C D GS1 128 Scanned data 0 1 PI X1 X2 X3 X4 X5 X6 X7 X8 X9 X10 X11 X12 X13 C ...
Page 82: ... that there are instances when the scanner cannot confirm the ACK or NAK response even when data has been sent to the host successfully Use the scanner in an environment that allows stable wireless communication There are two methods of data packing data packing host and data packing BA Note The data packing function cannot be used when HID Human Interface Device Profile is selected Data packing h...
Page 83: ...bit to the left When there are too many digits due to the shift XOR the 1021h at the CRC value 4 Shift the retrieved data 1 bit to the left When there are too many digits due to the shift XOR the 0001h at the CRC value 5 Repeat the calculations in 3 and 4 8 times 6 Retrieve the second data byte 13h 7 Repeat the calculations in 3 and 4 8 times 8 Repeat this calculation up to the final byte 9 Finall...
Page 84: ...nner setting Data packing BA Communications adapter setting Communication with AT GT series 1 Data packetized and sent 2 ACK is sent when data is received successfully NAK is sent if not successfully received 3 Data sent to host after ACK is sent 1 Data packetized and sent 2 Received packet analyzed 3 ACK is sent when data is received successfully NAK is sent if not successfully received Bluetooth...
Page 85: ...t temperature between 10 C and 40 C Locations with humidity between 20 and 80 Locations with little dust and no excessive vibration Locations which will not come into contact with water Do not place the scanner or rechargeable battery cartridge in direct sunlight closed vehicles etc or in high temperature locations Avoid charging in locations where noise etc is present such as near general telepho...
Page 86: ...n the scanner indicator LED illuminates in red Charging time is approximately 2 5 hours When battery is fully charged the indicator LED changes to green 3 Remove the scanner from the battery charger and unplug the AC adapter from the socket Operation and charging status Scanner indicator LED Set the scanner on the battery charger Red light Charging begins Red light After approximately 2 5 hours Ch...
Page 87: ...urthermore follow the procedure below to remove the rechargeable battery cartridge when the scanner has malfunctioned 1 Remove the screw of the lower housing on the bottom of the scanner 2 Open the lower housing Open the housing carefully as a cable is connected to the lower housing 3 Remove the rechargeable battery cartridge from the scanner 4 Disconnect the battery cable connector Note Always ho...
Page 88: ...e When closing the lower housing take care not to jam the cable between the housing and bottom housing Note Be sure to charge the new rechargeable battery cartridge following replacement Note Never peel off the protective film covering the rechargeable battery cartridge Rechargeable battery cartridge Rechargeable battery cartridge Battery cable connector Rechargeable battery cartridge Lower housin...
Page 89: ... your nearest cooperating rechargeable battery recycler or contact your nearest Denso office Pay careful attention to the following points when placing the used rechargeable battery cartridge into the recycling box of a recycler In order to prevent heat generation and fire caused by a short cover the connector with cellophane tape etc and place it in the box in an insulted state Never remove the v...
Page 90: ...becomes narrower but the quality of the image does not deteriorate An image transfer function allows the image to be made into a thumbnail for ease of selection Thumbnail size can be selected from 1 64 WVGA in bitmap format and 1 4 WVGA in JPEG format Parameters such as output format image size image format and whether to create thumbnails can be changed via the image output settings command IMAGE...
Page 91: ...5 Operation 1 When the scanner receives the IMAGEOUT command it captures the image and the beeper sounds three times The scanner then enters image transmission mode Xmodem 1K Protocol 2 When thumbnail transmission is enabled Thumbnails 1 64 WVGA BMP files 1 4 WVGA JPEG files are repeatedly transmitted When the trigger switch is pulled the scanner captures the image and begins image transmission Xm...
Page 92: ...the image is compressed during conversion to JPEG format image quality may deteriorate 7 Image Transmission Time Standard Value The communications adapter BA11 RKU or BA20 RU interface uses RS 232 Communications condition displays the standard speed of image capture conversion and transmission when the protocol is Xmodem 1K and the transmission speed is 115200 bps As a result transmission time wil...
Page 93: ...erification mode 2 point verification mode Data edit mode Unedited Section 7 2 Data extraction mode Data conversion mode Block sorting mode ADF script mode Point scan mode Enabled Section 7 4 Disabled Double scan prevention time Double scan enabled Section 3 2 Double scan prevention time Set range 0 1 9 9 s 1 s Only available via configuration software 2 Customizing Communications Mode Parameters ...
Page 94: ... 1 Note 1 CAPS LOCK on Keyboard type U S English 101 Keyboard Section 9 3 2 Germany 102 Keyboard French 102 Keyboard U K English 102 Keyboard Italian 102 Keyboard Swedish 102 Keyboard Japanese 106 Keyboard Numerical data 0 9 transmission format Inboard numeric keys Section 9 3 3 Note 3 Numeric keys Binary data conversion Note 2 None ASCII conversion Section 9 3 4 Binary conversion Kanji conversion...
Page 95: ... data other than the communication format header terminator When special key transmission is enabled data from E7h to FDh is substituted with special keys according to the special key conversion table below and then transmitted Left SHIFT left CTRL and left ALT will be transmitted when the character or key set subsequently is pressed at the same time Upper Digit Lower Digit E F 0 1 F1 2 F2 3 F3 4 ...
Page 96: ...Section 2 1 Note 1 End operation PIN code One to eight alphanumeric characters 1234 Appendix 3 Security function Disabled Enabled Local device ID Other devices Keyboard peripheral Auto power off Setting range 5 640 minutes 60 minutes Section 3 2 Disabled Only available via configuration software Note 1 Factory settings Set to End operation 6 Data Transmission Format Specification when SPP profile ...
Page 97: ... set Settings Parameters Default Refer to Header None Section 9 4 1 STX ETX CR LF CR LF TAB ESC ENTER Execute right CTRL User selection Terminator None STX ETX CR LF CR LF TAB ESC ENTER Execute right CTRL User selection Only available via configuration software ...
Page 98: ...nsmission enabled Section 9 4 6 2 digit transmission enabled Transfer disabled Prefix transmission Transmission enabled Section 9 4 3 Transfer disabled Suffix transmission Transmission enabled Transfer disabled Scanner ID output Transmission enabled Section 9 4 2 Transfer disabled GTIN Conversion Enabled Section 9 5 Disabled GTIN EAN JAN conversion type Conversion to 14 digits Conversion to 13 dig...
Page 99: ... QR Code minimum scannable version Setting range 1 40 1 Note 3 QR Code maximum scannable version 40 Micro QR Code minimum scannable version Setting range 1 4 1 Micro QR Code maximum scannable version 4 Data Matrix square minimum scannable code no Setting range 1 24 1 Data matrix square maximum scannable code no 24 Data matrix rectangular minimum scannable code no Setting range 1 6 1 Data matrix re...
Page 100: ...imum scannable version 61 iQR Code rectangular scanning Scanning enabled Scanning disabled iQR Code rectangular minimum scannable version Setting range 1 15 1 Note 1 iQR Code rectangular maximum scannable version 15 iQR code split mode scanning Edit mode Section 7 7 Non edit mode Aztec Full Range scanning Enabled Disabled Aztec Compact scanning Enabled Disabled Aztec Full Range minimum scannable l...
Page 101: ...ntry code transmission Transmission enabled Section 9 4 7 Note 1 Transfer disabled EAN 13 ISBN ISSN conversion Conversion enabled Section 9 4 7 Conversion disabled UPC E Code scanning Enabled Disabled UPC E C D transmission Transmission enabled Section 9 4 7 Transfer disabled UPC E number system character transmission Transmission enabled Transfer disabled Transmission of UPC E padding character f...
Page 102: ...l Disabled Settings range level 1 4 Only available via configuration software Interleaved 2 of 5 Settings Parameters Default Refer to Interleaved 2 of 5 scanning Scanning enabled without check digit Scanning enabled with check digit check digit transmission enabled Scanning enabled with check digit check digit transmission disabled Disabled Interleaved 2 of 5 minimum scannable digits 2 99 digits 4...
Page 103: ...differ Codabar NW 7 Settings Parameters Default Refer to Codabar NW 7 scanning Scanning enabled without check digit Scanning enabled with check digit check digit transmission enabled Scanning enabled with check digit check digit transmission disabled Disabled Codabar NW 7 minimum scannable digits 3 99 digits incl start stop code 4 digits Note 2 Codabar NW 7 maximum scannable digits 99 digits Codab...
Page 104: ...er Code 128 GS1 128 Settings Parameters Default Refer to Code 128 scanning Enabled Note 3 Disabled GS1 128 scanning Enabled Disabled Code 128 minimum scannable digits 1 99 digits excl start stop code and 1 digit check digit 1 digit Note 2 Code 128 maximum scannable digits 99 digits Code 128 FNC1 transmission Transfer disabled Section 9 4 7 Convert to GS and transmit User selection GS1 128 minimum ...
Page 105: ...nded Stacked scanning Enabled Disabled GS1 DataBar Expanded minimum scannable digits 1 99 digits 1 digit GS1 DataBar Expanded maximum scannable digits 99 digits Transmission of FNC1 for GS1 DataBar Expanded code Transfer disabled Section 9 4 7 Convert to GS and transmit User selection GS1 Composite scanning Enabled Note 3 Disabled GS1 DataBar Composite with CC A scanning Enabled Disabled Note 2 GS...
Page 106: ...nator Comma 1st line barcode code type Specified from scannable codes Not specified 1st line barcode lead character Specified by up to two ASCII characters Not specified 1st line barcode minimum scannable digits Maximum 99 digits Not specified 1st line barcode maximum scannable digits Maximum 99 digits Not specified 2nd line barcode code type Specified from scannable codes Not specified 2nd line b...
Page 107: ...ction 5 1 1 One shot 1 s One shot 2 s One shot 3 s One shot 4 s One shot 5 s Auto stand mode to auto sensing mode switching method Manual Section 5 3 Automatic Auto stand mode to auto sensing mode switching time 1 s Section 5 3 2 s 3 s 4 s 5 s 6 s 7 s 8 s 9 s Error transmission when scanning fails ERROR transmission enabled Section 5 1 Transmission disabled Scanner sensitivity level in auto sensin...
Page 108: ...tching function Marker switching function Barcode reader mode switching function Auto sensing mode switching function No function assigned Magic key Bluetooth disconnection Enabled Chapter 6 Disabled Operation following Bluetooth disconnection via pressing the magic key Reconnection by pulling the trigger switch Chapter 6 Host connection standby Only available via configuration software ...
Page 109: ...tes when OK Section 8 3 Vibrates when NG Vibration disabled Marker illumination Marker off mode Section 8 4 Standard marker mode Marker on mode Illumination light LED Disabled Section 8 5 Enabled Illumination light LED ECO mode Enabled Note 1 Section 8 5 Disabled Only available via configuration software Note 1 As the brightness of the illumination LED is restricted users will need to scan at clos...
Page 110: ...abled Disabled Verification range Code type code data Code data only Applicable codes for data editing Specified from codes Any code Note 1 Section 7 2 Data editing error processing Transmit data regardless of the results Transmit data when successful Data Extraction Mode during data editing Data string extraction Data block extraction AI mode Data string extraction start position First character ...
Page 111: ...lock sorting mode output order BLOCK 1 5 BLOCK 1 BLOCK 2 AI mode AI split mode AI parenthesis mode AI split mode AI1 designation enabled disabled Enabled Disabled AI Split Mode AI2 designation enabled disabled Enabled Disabled AI split mode AI3 designation enabled disabled Enabled Disabled AI split mode AI1 designated Specified from AI candidates Note 1 00 AI split mode AI2 designated Specified fr...
Page 112: ... times Setting to All default will return all parameters to default settings The default is indicated with in the QR coded parameter menu Note Easy connection setting This parameter makes scanning the Setting commencement and Setting completion QR codes unnecessary Beeper volume adjustment This parameter makes scanning the Setting commencement and Setting completion QR codes unnecessary Scanning t...
Page 113: ...one iPad HID Profile Android HID Profile Android Windows PC SPP Profile Windows PC HID Profile 1 Scan the Easy connection setting QR code after setting other parameters When setting parameters after scanning the Easy connection setting barcode connection settings may be overwritten The following setting can be made just by scanning the QR codes with this parameter without needing to scan the Setti...
Page 114: ...101 Setting Commencement Setting Completion Defaults Setting commencement Setting commencement Cancel All Default Setting completion ...
Page 115: ...ng the Bluetooth disconnect scanning QR code allows scanning when Bluetooth wireless communication has been disconnected In this state data cannot be transmitted to or from the host computer Bluetooth disconnect scanning Cancel Bluetooth disconnect scanning Slave setting Scanning the following code will allow the user to set the scanner as a slave Set as slave ...
Page 116: ...cation Communication procedures Non acknowledge mode ACK NAK mode Header when SPP profile set None STX Header when HID profile set None TAB Enter Terminator when SPP profile set None ETX CR LF CR LF Terminator when HID profile set None TAB Enter CR LF CR LF ...
Page 117: ...10 minutes 30 minutes Keyboard type when HID profile set U S English 101 key Keyboard Japanese 106 key Keyboard Transmission Format Code mark transmission Disabled Enabled Digit no transmission Disabled 2 digit transmission enabled 4 digit transmission enabled ...
Page 118: ...de Black and white Inversion Micro QR Code scanning Disabled Enabled Black and white inverted code scanning Black and white normal code Black and white inverted code Black and white auto detect Split QR Code Edit mode Non edit Mode Split QR Code batch edit ...
Page 119: ...106 PDF417 scanning Disabled Enabled MaxiCode scanning Disabled Enabled Data Matrix scanning Disabled Enabled Scannable Barcode Settings UPC A UPC E EAN 13 EAN 8 scanning Disabled Enabled ...
Page 120: ...eck digit enabled Scanning with check digit enabled Check digit transmission enabled Code 128 GS1 128 scanning Disabled Enabled Codabar NW 7 scanning Disabled Scanning without check digit enabled Scanning with check digit enabled Check digit transmission enabled Scanning with check digit enabled Check digit transmission disabled ...
Page 121: ...anning Disabled Scanning without check digit enabled Scanning with check digit enabled Check digit transmission enabled Scanning with check digit enabled Check digit transmission disabled Code 39 start stop code transmission Disabled Enabled Code 93 scanning Disabled Enabled ...
Page 122: ...te scanning Disabled Enabled Other Settings Trigger switch control Auto off mode Alternate switching mode Momentary switching mode Momentary switching mode reverse type Continuous reading mode 1 Continuous reading mode 2 Auto sensing mode Auto stand mode ...
Page 123: ... magic key Host connection standby Reconnection by pulling the trigger switch Beeper control Sound disabled Sound enabled Indicator LED Illumination disabled Illumination enabled Vibrator Vibrates when OK Vibrates when NG Vibration disabled ECO mode Disabled Enabled ...
Page 124: ... from settings mode Communications adapter interface power LED Flashes in orange Bluetooth status indicator LED blue Slow flash when set as a slave and waiting for connection Scanner Bluetooth wireless link connection Use the scanner which has stored parameters for the communications adapter to read the barcode on the back of the communications adapter The scanner beeper will sound three times and...
Page 125: ...tting the Communications Adapter Setting Commencement Setting Completion Defaults Setting commencement Setting commencement Cancel All Default Setting completion Specifying Interface USB keyboard interface RS 232C Interface USB COM Interface ...
Page 126: ...the USB COM Interface CTS control USB COM interface Not controlled Controlled Specifying RS 232C Interface Communications Parameters Transmission speed RS 232C interface 1200bps 2400bps 4800bps 9600bps 14400bps 19200bps 38400bps 57600bps 115200bps ...
Page 127: ... Word length RS 232C interface 7 bits 8 bits Parity RS 232C interface Disabled Even number Odd number Stop bit RS 232C interface 1 bit 2 bits CTS signal control RS 232C interface Not controlled Controlled ...
Page 128: ...115 Specifying Communications Parameters for the USB Keyboard Interface Specifying USB keyboard interface keyboard type default U S English German French U K English Italian Japan Swedish ...
Page 129: ...ta is not correctly displayed on the computer Things to check Measures Is the connecting Bluetooth device able to communicate See the manual for the connecting Bluetooth device Is the connecting Bluetooth device too far away Bring the scanner and the Bluetooth device closer together Is there a connection to the connecting Bluetooth device Connect the connecting Bluetooth device Is Bluetooth discon...
Page 130: ...ain power supply Lithium ion battery cartridge Environmental conditions Operating temperature range 20 to 50 C Operating humidity range 10 90 RH 5 Storage temperature range 20 to 60 C Storage humidity range 5 95 RH 5 Operating illumination range 10 000 lx or less External dimensions 92 184 73 mm Weight Approximately 230 g including rechargeable battery cartridge 1 Please contact separately when us...
Page 131: ...tilized when HID Human Interface Device Profile is selected Note 2 A command will not be initiated until the preceding command is completed 1 Command only consist of the command field Command Direction Contents Scanner Host Z Note 1 Scanning standby Only when the trigger switch is set to continuous reading mode 1 or mode 2 the scanner will enter the scanning standby mode by receiving Z READOFF or ...
Page 132: ...o U8 are stored in the internal FLASH ROM If no command is issued these values do not remain when the power is turned OFF and original values return VER Firmware version request Response from the scanner Ver n nn n nn Version No example Ver 1 00 VERF Setting parameter version request Check the setting parameter version required to generate a batch setting QR Code when not connected to the scanner ...
Page 133: ...ned data is transmitted by the receipt of the R command the scanned data is transmitted again This is because the Z command clears the prevention of double scanning For the same reason if the scanner enters the scanning standby mode by the receipt of the Z command before all the blocks of a Structured Append Code are completely scanned the Structured Append Code data are cleared However even when ...
Page 134: ...digits minimum numbers of digits maximum numbers of digits Each option must delimit by a comma A comma is required even if an option is not set A comma is omissible if rest of the sub sequential options is not required to set Example S Check digits Not omissible Note 1 Omissible Note 1 If the option fields are not set code scanning instructed by the command will be disabled Up to six commas can be...
Page 135: ...nal R1 R99 Specify Scan code and Check digit by the alphabet symbol minimum and maximum number of digits by the alphabet symbol followed by one or two digits of numeric number s Settable range is from the minimum number of digits to the maximum number of digits The default value shown on the table above is set if the minimum and maximum number of digits are not set Note 1 An error occurs if the sy...
Page 136: ...ber of digits Interleaved 2 of 5 4 20 digits Codabar NW 7 5 digits Code 39 8 99 digits Format of the command option field of the command D D Scan dodes Code types minimum versions maximum versions Each option must delimit by a comma A comma is required even if an option is not set A comma is omissible if rest of the sub sequential options is not required to set Example D Code types Not omissible N...
Page 137: ...sion for DataMatrix is defined as shown on the table below Data Matrix Square Version No of cells ROW COL Version No of cells ROW COL Version No of cells ROW COL Version No of cells ROW COL 1 10 10 7 22 22 13 44 44 19 88 88 2 12 12 8 24 24 14 48 48 20 96 96 3 14 14 9 26 26 15 52 52 21 104 104 4 16 16 10 32 32 16 64 64 22 120 120 5 18 18 11 36 36 17 72 72 23 132 132 6 20 20 12 40 40 18 80 80 24 144...
Page 138: ...t device Once the device is authenticated for the first time there is no need to enter the PIN Code again for subsequent connections Also called a Bluetooth Passkey Local name Bluetooth Device Name A user friendly name the Bluetooth device uses to identify itself Bluetooth wireless communication The communication line which connects the master device and the slave device When Bluetooth wireless co...
Page 139: ...2D code handy scanner GT20Q SB Manual December 2015 First Edition DENSO WAVE INCORPORATED AUTO ID Business Unit ...
Page 140: ...1 Yoshiike Kusagi Agui chô Chita gun Aichi 470 2297 JAPAN http www denso wave com ...