ASDA-M Chapter 8 Parameters
Revision December, 2014
8-65
Settings
:
If the setting is wrong, the servo motor will easily have sudden
unintended acceleration.
Please follow the rules for setting:
The setting of pulse input:
Range of command pulse input : 1
/
50
<
Nx
/
M
<
25600
NOTE
1) The setting value cannot be changed when Servo ON neither
in PT nor in PR mode.
P1-46
▲
GR3
Pulse Number of Encoder Output
Address: 015CH
015DH
Parameter
Attribute
:
Parameter for individual axis
Related Section: -
Operational
Interface
:
Panel / Software
Communication
Default
:
2500
Control
Mode
:
ALL
Unit
:
Pulse
Range
:
20 ~ 320000
Data Size
:
32bit
Format
:
DEC
Settings
:
The number of pulse output per revolution.
NOTE
The following circumstances might exceed the max. allowable
input pulse frequency and occurs AL018:
1. Abnormal encoder
2. The motor speed is faster than the setting of P1-76.
3.
6
10
19.8
4
46
1
P
60
Speed
Motor