Chapter 8 Parameters ASDA-M
8-196
Revision December, 2014
Command code 0004h
Motion parameter protection: unlock the
protection
Macro parameters
P5-96= enter the password (1~16777215)
This function can be executed when activating the function of parameter
protection.
If the protection function is unlocked, repeatly execute this function will sent
back the failure code.
If enter the wrong password, failure code Ennn will be sent back. nnn means
the rest decode number. It will be minused one number after one failure.
When the number is 0, it will be locked for good.
Failure code F041h
Protection function is unlocked and it cannot be
repeatly unlocked.
Failure code F043h
The password setting exceed the allowable range
(1~16777215).
Failure code F044h
The number of times of entering wrong password
exceeds the limit: Lock for good.
Reset the parameter (P2-08=10) to unlock it is
the only method. However, all parameter will
return to the default value.
Failure code Ennnh
Incorrect password setting: Failed to unlock.
nnn: the rest decode number. It will be minused
one number after one failure. When the number is
0, it will be locked for good.
Success code: 1004h
P5-98
EVON
PR# Triggered by Event Rising-Edge
Address: 05C4H
05C5H
Parameter
Attribute
:
Parameter for individual axis
Related Section:-
Operational
Interface
:
Panel / Software
Communication
Default
:
0
Control
Mode
:
PR
Unit
:
-
Range
:
0000 ~ 0xDDDD