ASDA-M Chapter 8 Parameters
Revision December, 2014
8-103
Data Size
:
16bit
Format
:
DEC
Settings
:
The second setting value of resonance frequency. If P2-44 is set
to 0, this function is disabled. P2-23 and P2-24 are the first
Notch filter.
P2-44
DPH2
Resonance Suppression (Notch filter)
Attenuation Rate (2)
Address: 0258H
0259H
Parameter
Attribute
:
Parameter for individual axis
Related Section:
Section 6.3.7
Operational
Interface
:
Panel / Software
Communication
Default
:
0
Control
Mode
:
ALL
Unit
:
dB
Range
:
0 ~ 32 (0: disable Notch filter)
Data Size
:
16bit
Format
:
DEC
Settings
:
The second resonance suppression (notch filter) attenuation rate.
When this parameter is set to 0, the function of Notch filter is
disabled.
P2-45
NCF3
Resonance Suppression (Notch filter)
(3)
Address: 025AH
025BH
Parameter
Attribute
:
Parameter for individual axis
Related Section:
Section 6.3.7
Operational
Interface
:
Panel / Software
Communication
Default
:
1000
Control
Mode
:
ALL
Unit
:
Hz
Range
:
50 ~ 2000
Data Size
:
16bit
Format
:
DEC