Chapter 8 Parameters ASDA-M
8-38
Revision December, 2014
P1-xx Basic Parameters
P1-00
▲
PTT
The Type of External Pulse Input
Address: 0100H
0101H
Parameter
Attribute
:
Parameter for individual axis
Related Section:
Section 6.2.1
Operational
Interface
:
Panel / Software
Communication
Default
:
0x2
Control
Mode
:
PT
Unit
:
-
Range
:
0 ~ 0x1142
Data Size
:
16bit
Format
:
HEX
Settings
:
Pulse
Type
0: AB phase pulse (4x)
1: Clockwise (CW) and Counterclockwise (CCW) pulse
2: Pulse + symbol
Other setting: reserved
Filter
Width
If the received frequency is much higher than the setting, it will be
regarded as the noise and filtered out.
Setting
Value
Low-speed filter
frequency
(Min. pulse width*
note1
)
Setting
Value
High-speed filter
frequency
(Min. pulse width*
note1
)
0
0.83Mpps (600ns)
0 3.33Mpps
(150ns)
1
208Kpps (2.4us)
1 0.83Mpps
(600ns)
2
104Kpps (4.8us)
2 416Kpps
(1.2us)
3
52Kpps (9.6us)
3 208Kpps
(2.4us)
4
No filter function
4
No filter function