Chapter 7 Servo Parameters
|
ASDA-AB Series
Revision January 2009
7-53
P2 - 06
KVI
Speed Integral Compensation
Communication Addr.: 0206H
Default: 100
Related Section:
Applicable Control Mode: ALL
Section 6.3.6
Unit: N/A
Range: 0 ~ 4095
Settings:
This parameter is used to set the integral time of speed loop. When the value of speed integral
compensation is increased, it can improve the speed response ability and decrease the speed
control deviation. However, if the setting value is over high, it may generate vibration or noise.
P2 - 07
SFG
Speed Feed Forward Gain
Communication Addr.: 0207H
Default: 0
Related Section:
Applicable Control Mode: ALL
Section 6.3.6
Unit: 0.0001
Range: 0 ~ 20000
Settings:
This parameter is used to set the feed forward gain when executing speed control command.
When using speed smooth command, increase gain can improve speed track deviation.
When not using speed smooth command, decrease gain can improve the resonance condition of
mechanical system.