Chapter 7 Servo Parameters
|
ASDA-AB Series
7-48
Revision January 2009
P1 - 52
RES1
Regenerative Resistor Value
Communication Addr.: 0134H
Default: 40 (1kW and below), 20 (above 1kW)
Related Section:
Applicable Control Mode: ALL
Section 6.6.3
Unit: Ohm
Range: 10 ~ 750
P1 - 53
RES2
Regenerative Resistor Capacity
Communication Addr.: 0135H
Default: 60 (1.5kW and below), 120 (above 1.5kW)
Related Section:
Applicable Control Mode: ALL
Section 6.6.3
Unit: Watt
Range: 30 ~ 1000
P1 - 54
PER
Positioning Completed Width
Communication Addr.: 0136H
Default: 100
Related Section: N/A
Applicable Control Mode: Pt , Pr
Unit: Pulse
Range: 0 ~ 10000
Settings:
This parameter is used to set the width of pulse output range in which TPOS (positioning
completed signal) will activate. For Example, at factory default TPOS (positioning completed
signal) will activate once the motor is in -99 pulses range of the target position, then deactivate
after it r99 pulses range of the desired position.
P1 - 55
MSPD Maximum Speed Limit
Communication Addr.: 0137H
Default: rated speed
Related Section: N/A
Applicable Control Mode: ALL
Unit: r/min
Range: 0 ~ Max. speed
Settings:
This parameter is used to set maximum motor speed. The default setting is rated speed.
Summary of Contents for AC Servo Drive ASDA-AB
Page 1: ......
Page 13: ...Table of Contents ASDA AB Series Revision January 2009 This page intentionally left blank...
Page 85: ...Chapter 5 Trial Run and Tuning Procedure ASDA AB Series 5 8 Revision January 2009...
Page 246: ...Chapter 8 MODBUS Communications ASDA AB Series Revision January 2009 8 3 Cable Connection...
Page 307: ...Chapter 12 Application Examples ASDA AB Series 12 10 Revision January 2009...