P1 - 34
TACC Acceleration Time
Communication Addr.: 0122H
Default: 200
Related Section:
Applicable Control Mode: Pr, S
P1-35, P1-36, Section 6.3.3
Unit: ms
Range: 1 ~ 20000
Settings:
1st to 3rd step acceleration time.
It is used to determine the acceleration time to accelerate from 0 to its rated motor speed. (When
P1-36 is set to 0: Accel/Decel function is disabled, i.e. P1-34, P1-35 is disabled.)
P1 - 35
TDEC Deceleration Time
Communication Addr.: 0123H
Default: 200
Related Section:
Applicable Control Mode: Pr, S
P1-34, P1-36, Section 6.3.3
Unit: ms
Range: 1 ~ 20000
Settings:
1st to 3rd step deceleration time.
It is used to determine the deceleration time to decelerate from its rated motor speed to 0.
(When P1-36 is set to 0: Accel/Decel function is disabled, i.e. P1-34, P1-35 is disabled.)