Chapter 7 Servo Parameters
|
ASDA-AB Series
7-44
Revision January 2009
P1 - 45
▲
GR2
Electronic Gear Ratio (Denominator)
Communication Addr.: 012DH
Default: 1
Related Section:
Applicable Control Mode: Pt, Pr
Section 6.3.6
Unit: Pulse
Range: 1 ~ 32767
Settings:
Electronic gear denominator setting.
It is recommended to set electronic gear ratio when the servo drive is Off. As the wrong setting
may cause motor to run chaotically (out of control) and it may lead to personnel injury, therefore,
ensure to observe the following rule when setting P1-44, P1-45.
The electronic gear ratio setting (Please also see P1-44, P2-60 ~ P2-62):
f1
f2 = f1 x
N
M
N
M
Pulse input
Position
command
f1: Pulse input
f2: Position command
N: Numerator 1, 2, 3, 4, the setting value of P1-44 or P2-60 ~ P2-63
M: Denominator, the setting value of P1-45
The electronic gear ratio setting range must be within: 1/50<N/M<200.
Summary of Contents for AC Servo Drive ASDA-AB
Page 1: ......
Page 13: ...Table of Contents ASDA AB Series Revision January 2009 This page intentionally left blank...
Page 85: ...Chapter 5 Trial Run and Tuning Procedure ASDA AB Series 5 8 Revision January 2009...
Page 246: ...Chapter 8 MODBUS Communications ASDA AB Series Revision January 2009 8 3 Cable Connection...
Page 307: ...Chapter 12 Application Examples ASDA AB Series 12 10 Revision January 2009...