P0 - 02
STS
Drive Status
Communication Addr.: 0002H
Default: 00
Related Section:
Applicable Control Mode: ALL
Section 4.3.5
Unit: N/A
Range: 00 ~ 16
Settings:
00: Motor feedback pulse number (absolute value) [pulse]
01: Motor feedback rotation number (absolute value) [rev]
02: Pulse counts of pulse command [pulse]
03: Rotation number of pulse command [rev]
04: Position error counts [pulse]
05: Input frequency of pulse command [Kpps]
06: Motor speed [r/min]
07: Speed input command [Volt]
08: Speed input command [r/min]
09: Torque input command [Volt]
10: Torque input command [%]
11: Average load [%]
12: Peak load [%]
13: Main circuit voltage [Volt]
14: Ratio of load inertia to motor inertia [time]
15: Motor feedback pulse number (relative value) / Position latch pulse number [pulse]
16: Motor feedback rotation number (relative value) / Position latch rotation number [rev]