Revision January 2009
6-1
Chapter 6 Control Modes of Operation
6.1 Control Modes of Operation
The Delta ASDA-AB series
can be programmed to provide six single and five dual modes of operation. Their
operation and description is listed in the following table.
Mode
Code
Description
External Position Control
Pt
Position control for the servo motor is achieved via an
external pulse command.
Internal Position Control
Pr
Position control for the servo motor is achieved via by 8
commands stored within the servo controller. Execution of
the 8 positions is via Digital Input (DI) signals.
Speed Control
S
Speed control for the servo motor can be achieved via
parameters set within the controller or from an external
analog -10 ~ +10 V
DC
command. Control of the internal
speed parameters is via the Digital Inputs (DI). (A maximum
of three speeds can be stored internally).
Internal Speed Control
Sz
Speed control for the servo motor is only achieved via
parameters set within the controller. Control of the internal
speed parameters is via the Digital Inputs (DI). (A maximum
of three speeds can be stored internally).
Torque Control
T
Torque control for the servo motor can be achieved via
parameters set within the controller or from an external
analog -10 ~ +10 V
DC
command. Control of the internal
torque parameters is via the Digital Inputs (DI). (A
maximum of three torque levels can be stored internally).
Single
Mode
Internal Torque Control
Tz
Torque control for the servo motor is only achieved via
parameters set within the controller. Control of the internal
torque parameters is via the Digital Inputs (DI). (A
maximum of three torque levels can be stored internally).
Pt-S Either Pt or S control mode can be selected via the Digital
Inputs (DI)
Pt-T Either Pt or T control mode can be selected via the Digital
Inputs (DI)
Pr-S Either Pr or S control mode can be selected via the Digital
Inputs (DI)
Pr-T Either Pr or T control mode can be selected via the Digital
Inputs (DI)
Dual Mode
S-T
Either S or T control mode can be selected via the Digital
Inputs (DI)
The steps of changing mode:
(1)
Switching the servo drive to Servo Off status. Turning SON signal of Digit input to be off can complete
this action.
(2)
Using parameter P1-01. (Refer to chapter 7).
(3)
After the setting is completed, cut the power off and restart the drive again.
Summary of Contents for AC Servo Drive ASDA-AB
Page 1: ......
Page 13: ...Table of Contents ASDA AB Series Revision January 2009 This page intentionally left blank...
Page 85: ...Chapter 5 Trial Run and Tuning Procedure ASDA AB Series 5 8 Revision January 2009...
Page 246: ...Chapter 8 MODBUS Communications ASDA AB Series Revision January 2009 8 3 Cable Connection...
Page 307: ...Chapter 12 Application Examples ASDA AB Series 12 10 Revision January 2009...