Troubleshooting
267
Troubleshooting Sled Components
The following procedures describe how to troubleshoot the following
compute sled components:
• Memory
• Hard-drives
• Expansion cards
• Processors
• System board
• Battery
Troubleshooting System Memory
CAUTION:
Many repairs may only be done by a certified service technician. You
should only perform troubleshooting and simple repairs as authorized in your
product documentation, or as directed by the online or telephone service and
support team. Damage due to servicing that is not authorized by Dell is not covered
by your warranty. Read and follow the safety instructions that came with the
product.
NOTE:
Invalid memory configurations can cause your system to halt at startup
without video output. See the compute sled’s
Hardware Owner’s Manual
for
information about the "System Memory" and verify that your memory configuration
complies with all applicable guidelines.
1
If the system is not operational, turn off the sled and attached peripherals.
2
After 10 seconds, turn on the sled and attached peripherals and note the
messages on the screen.
Go to step 11 if an error message appears indicating a fault with a specific
memory module.
3
Enter the System Setup program and check the system memory settings.
See "Main Menu" on page 74. Make any changes to the memory settings, if
needed.
If the memory settings match the installed memory but a problem is still
indicated, go to step 11.
4
Turn off the sled and attached peripherals.
Summary of Contents for PowerEdge C8000
Page 1: ...Dell PowerEdge C8000 Hardware Owner s Manual Regulatory Model B10S Regulatory Type B10S001 ...
Page 41: ...About the System 41 Figure 1 24 Service Tag Location for C8000XD Storage Sled ...
Page 160: ...160 Using the System Setup Program MIB Tree Diagram for FCB ...
Page 170: ...170 Using the System Setup Program MIB Tree Diagram for PMC ...
Page 185: ...Using the System Setup Program 185 ...
Page 186: ...186 Using the System Setup Program ...
Page 220: ...220 Installing System Components ...
Page 250: ...250 Rack Mount Configuration ...
Page 274: ...274 Troubleshooting ...
Page 288: ...288 Jumpers and Connectors ...
Page 290: ...290 Getting Help ...