About the System
47
002Fh No Microcode
Be Updated
Pause
Processor
microcode load
failed
Ensure that your processors
match and conform to the
type described in the
processor technical
specifications outlined in
your system’s Getting Started
Guide.
8012h SATA 0 Device
Not Found
Pause
SATA 0 device
not found
Check if the SATA port 0 is
enabled. See "SATA
Configuration" on page 95.
Install a SATA device to SATA
port 0.
If the problem persists, see
"Getting Help" on page 289.
8013h SATA 1 Device
Not Found
Pause
SATA 1 device
not found
Check if the SATA port1 is
enabled. See "SATA
Configuration" on page 95.
Install a SATA device to SATA
port 1.
If the problem persists, see
"Getting Help" on page 289.
8014h SATA 2 Device
Not Found
Pause
SATA 2 device
not found
Check if the SATA port 2 is
enabled. See "SATA
Configuration" on page 95.
Install a SATA device to SATA
port 2.
If the problem persists, see
"Getting Help" on page 289.
8015h SATA 3 Device
Not Found
Pause
SATA 3 device
not found
Check if the SATA port 3 is
enabled. See "SATA
Configuration" on page 95.
Install a SATA device to SATA
port 3.
If the problem persists, see
"Getting Help" on page 289.
Error
Code
Error Message
Response Error Cause
Corrective Actions
Summary of Contents for PowerEdge C8000
Page 1: ...Dell PowerEdge C8000 Hardware Owner s Manual Regulatory Model B10S Regulatory Type B10S001 ...
Page 41: ...About the System 41 Figure 1 24 Service Tag Location for C8000XD Storage Sled ...
Page 160: ...160 Using the System Setup Program MIB Tree Diagram for FCB ...
Page 170: ...170 Using the System Setup Program MIB Tree Diagram for PMC ...
Page 185: ...Using the System Setup Program 185 ...
Page 186: ...186 Using the System Setup Program ...
Page 220: ...220 Installing System Components ...
Page 250: ...250 Rack Mount Configuration ...
Page 274: ...274 Troubleshooting ...
Page 288: ...288 Jumpers and Connectors ...
Page 290: ...290 Getting Help ...