Rack Mount Configuration
249
NOTE:
When connected to a power source, main power is automatically
distributed to the PowerEdge C8000 server enclosure. After the server enclosure is
powered up the power/event indicator on the front of the enclosure will light up
green and main power is applied to all sleds in the enclosure.
4
Turn on the sleds in the server enclosure.
To turn on the C8220 or C8220X compute sled, press the power button on
each sled, or power on the sled using the baseboard management
controller. When power is applied to the sled, the power-on indicator on
front of the sled will light up green. When installed into the server
enclosure, the C8000XD storage sled automatically powers on.
The power/status indicator flashes amber indicating
the following conditions (
continued
):
• PSU module reading exceed threshold limits
• Power > 1480 W
• Voltage > 14.5 V
• Voltage < 10.75 V
• Current > 13 A
• Temperature > 60 °C
• Fan speed < 500 rpm
• PSU module status (from PSU STATUS_WORD)
• PSU module OVP
• PSU module OCP
• PSU module OTP
• PSU module fan fault protection (FFP)
• PSU module input over current
• PSU module input over power
• PSU module AC loss
• PSU module works in boot mode
• Communication error
Indicator
Icon
Description
Summary of Contents for PowerEdge C8000
Page 1: ...Dell PowerEdge C8000 Hardware Owner s Manual Regulatory Model B10S Regulatory Type B10S001 ...
Page 41: ...About the System 41 Figure 1 24 Service Tag Location for C8000XD Storage Sled ...
Page 160: ...160 Using the System Setup Program MIB Tree Diagram for FCB ...
Page 170: ...170 Using the System Setup Program MIB Tree Diagram for PMC ...
Page 185: ...Using the System Setup Program 185 ...
Page 186: ...186 Using the System Setup Program ...
Page 220: ...220 Installing System Components ...
Page 250: ...250 Rack Mount Configuration ...
Page 274: ...274 Troubleshooting ...
Page 288: ...288 Jumpers and Connectors ...
Page 290: ...290 Getting Help ...