144
Using the System Setup Program
4916
Chassis Level
Policy
Selects throttling as the chassis level policy when an
emergency throttling event is triggered. (default)
4917
Chassis Level
Policy
Selects power off as the chassis level policy when an
emergency throttling event is triggered.
4918
N/A
Disables clock spread spectrum. (default)
4919
N/A
Enables clock spread spectrum.
491A
Disables the PCIe memory 64-bit decode option.
491B
Enables the PCIe memory 64-bit decode option.
491C
Automatically configures to PCIe memory 64-bit
decode option.
4875
Perfmon and
DFX Devices
Disables Perfmon and DFX Devices.
4876
Perfmon and
DFX Devices
Enables Perfmon and DFX Devices.
4B00h
Prevent Back-
flash
When enabled, will prohibit the system BIOS to
downgrade to version 2.1.0 or earlier version.
NOTE:
You will not be able to change the setting once
the feature is enabled.
4B01h
Prevent Back-
flash
By default, this feature is set to disabled for the
compliance of updating the system BIOS. This token
works with the password jumper when the jumper is
set to enabled. When the setting is disabled, the
system BIOS can be updated to any revision that
contains a valid digital signature.
Table 2-1. D4 Token Table
(continued)
Token
Setup Option
Description
Summary of Contents for PowerEdge C8000
Page 1: ...Dell PowerEdge C8000 Hardware Owner s Manual Regulatory Model B10S Regulatory Type B10S001 ...
Page 41: ...About the System 41 Figure 1 24 Service Tag Location for C8000XD Storage Sled ...
Page 160: ...160 Using the System Setup Program MIB Tree Diagram for FCB ...
Page 170: ...170 Using the System Setup Program MIB Tree Diagram for PMC ...
Page 185: ...Using the System Setup Program 185 ...
Page 186: ...186 Using the System Setup Program ...
Page 220: ...220 Installing System Components ...
Page 250: ...250 Rack Mount Configuration ...
Page 274: ...274 Troubleshooting ...
Page 288: ...288 Jumpers and Connectors ...
Page 290: ...290 Getting Help ...