162
Using the System Setup Program
FCB
Control
fc Initiate
Upload
read-write values:
FC/CPLD/
NetConfig
v
v
Initiate upload
power
Consumption
read-only Integer
v
Power consumption
fcpsu
Configuration
read-write values:
x1n1, x2n0
v
PSU Configuration,
X1n1: X+N=1+1
X2n0: X+N=2+0
enable
Manual Fan
Control
read-write values:
1/0
v
Default is disabled (0)
manual Fan
Control Duty
Cycle
read-write integer
v
Manual Fan Control
Duty Cycle, 0 - 100,
default 100
FCB
FansTable
number Of
Fans
read-only integer
v
Number of FAN
fan Index
not-
accessible
Fan Index
fan Status
read-only values:
ok, error
v
FAN Status
fan Speed
Read-only integer
v
FAN Speed
sled Index
not-
accessible
v
Sled Index
FCB
Sleds
Table
sled Type
read-only values:
ok, na,
storage,
dummy, psu
v
Sled Type
psu Index
not-
accessible
v
PSU Index
Table 2-22. FCB SNMP MIB
Category
Object Name
Read/Write Value Type
Operation
FW
Safe
Boot FW
Note
Summary of Contents for PowerEdge C8000
Page 1: ...Dell PowerEdge C8000 Hardware Owner s Manual Regulatory Model B10S Regulatory Type B10S001 ...
Page 41: ...About the System 41 Figure 1 24 Service Tag Location for C8000XD Storage Sled ...
Page 160: ...160 Using the System Setup Program MIB Tree Diagram for FCB ...
Page 170: ...170 Using the System Setup Program MIB Tree Diagram for PMC ...
Page 185: ...Using the System Setup Program 185 ...
Page 186: ...186 Using the System Setup Program ...
Page 220: ...220 Installing System Components ...
Page 250: ...250 Rack Mount Configuration ...
Page 274: ...274 Troubleshooting ...
Page 288: ...288 Jumpers and Connectors ...
Page 290: ...290 Getting Help ...