References
256
QuickScan™ Lite QW2400
Flash Off Time
This feature specifies the OFF time for the indicator LED while in Flash Mode.
The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100
millisecond increments.
Follow these instructions to set this feature.
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the
result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05,
20 = 20, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Program-
ming Mode.
4. Scan the bar code: SELECT FLASH OFF TIME SETTING on
5. Scan the appropriate two digits from the keypad in
, that
represent the duration which was determined in the steps above. You will
hear a two-beep indication after the last character.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming
Mode.
This completes the procedure. See the table below for examples of how to set
this feature.
Table 16. Flash Off Time Setting Examples
NOTE
If you make a mistake before the last character, scan the CANCEL bar
code to abort and not save the entry string. You can then start again
at the beginning.
STEP
ACTION
EXAMPLES
1
Desired Setting
500ms
1,000ms (1 sec.) 5200ms (5.2 sec.)
9,900ms (9.9 sec.)
2
Divide by 100 (and pad with
leading zeroes to yield two
digits)
05
10
52
99
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT FLASH OFF TIME SETTING
5
Scan Two Characters From
‘0’ and ‘5’
‘1’ and ‘0’
‘5’ and ‘2’
‘9’ and ‘9’
6
Scan ENTER/EXIT PROGRAMMING MODE
Summary of Contents for QuickScan Lite QW2400
Page 12: ...Introduction 4 QuickScan Lite QW2400 NOTES...
Page 74: ...Keyboard Interface 66 QuickScan Lite QW2400 NOTES...
Page 90: ...Data Format 82 QuickScan Lite QW2400 NOTES...
Page 252: ...References 260 QuickScan Lite QW2400 NOTES...
Page 260: ...Technical Specifications 270 QuickScan Lite QW2400 NOTES...
Page 272: ...Standard Defaults 282 QuickScan Lite QW2400 NOTES...
Page 278: ...Keypad 288 QuickScan Lite QW2400 A B C D E F...