Enter/Exit Programming Mode
Code 39
136
QuickScan™ Lite QW2400
Code 39 Check Character Calculation
Enable this option to enable/disable calculation and verification of an optional
Code 39 check character. When disabled, any check character in the label is
treated as a data character.
$CC3CC00
Code 39 Check Character Calculation = Don’t Calculate
$CC3CC01
Code 39 Check Character Calculation = Calculate Std Check
$CC3CC02
Code 39 Check Character Calculation = Calculate Mod 7
Check
$CC3CC04
Code 39 Check Character Calculation = Enable Italian Post
Check
$CC3CC08
Code 39 Check Character Calculation = Enable Daimler
Chrysler Check
DEFAULT