4.1.6 3-** Reference/Ramps
Par.
No. #
Parameter description
Default value
4-set-up
FC 302
only
Change
during
operation
Conver-
sion index
Type
3-0* Reference Limits
3-00
Reference Range
null
All set-ups
TRUE
-
Uint8
3-01
Reference/Feedback Unit
null
All set-ups
TRUE
-
Uint8
3-02
Minimum Reference
App.Dependent
All set-ups
TRUE
-3
Int32
3-03
Maximum Reference
App.Dependent
All set-ups
TRUE
-3
Int32
3-04
Reference Function
[0] Sum
All set-ups
TRUE
-
Uint8
3-1* References
3-10
Preset Reference
0.00 %
All set-ups
TRUE
-2
Int16
3-11
Jog Speed [Hz]
App.Dependent
All set-ups
TRUE
-1
Uint16
3-12
Catch up/slow Down Value
0.00 %
All set-ups
TRUE
-2
Int16
3-13
Reference Site
[0] Linked to Hand / Auto
All set-ups
TRUE
-
Uint8
3-14
Preset Relative Reference
0.00 %
All set-ups
TRUE
-2
Int32
3-15
Reference Resource 1
null
All set-ups
TRUE
-
Uint8
3-16
Reference Resource 2
null
All set-ups
TRUE
-
Uint8
3-17
Reference Resource 3
null
All set-ups
TRUE
-
Uint8
3-18
Relative Scaling Reference Resource
[0] No function
All set-ups
TRUE
-
Uint8
3-19
Jog Speed [RPM]
App.Dependent
All set-ups
TRUE
67
Uint16
3-4* Ramp 1
3-40
Ramp 1 Type
[0] Linear
All set-ups
TRUE
-
Uint8
3-41
Ramp 1 Ramp up Time
App.Dependent
All set-ups
TRUE
-2
Uint32
3-42
Ramp 1 Ramp Down Time
App.Dependent
All set-ups
TRUE
-2
Uint32
3-45
Ramp 1 S-ramp Ratio at Accel. Start
50 %
All set-ups
TRUE
0
Uint8
3-46
Ramp 1 S-ramp Ratio at Accel. End
50 %
All set-ups
TRUE
0
Uint8
3-47
Ramp 1 S-ramp Ratio at Decel. Start
50 %
All set-ups
TRUE
0
Uint8
3-48
Ramp 1 S-ramp Ratio at Decel. End
50 %
All set-ups
TRUE
0
Uint8
3-5* Ramp 2
3-50
Ramp 2 Type
[0] Linear
All set-ups
TRUE
-
Uint8
3-51
Ramp 2 Ramp up Time
App.Dependent
All set-ups
TRUE
-2
Uint32
3-52
Ramp 2 Ramp down Time
App.Dependent
All set-ups
TRUE
-2
Uint32
3-55
Ramp 2 S-ramp Ratio at Accel. Start
50 %
All set-ups
TRUE
0
Uint8
3-56
Ramp 2 S-ramp Ratio at Accel. End
50 %
All set-ups
TRUE
0
Uint8
3-57
Ramp 2 S-ramp Ratio at Decel. Start
50 %
All set-ups
TRUE
0
Uint8
3-58
Ramp 2 S-ramp Ratio at Decel. End
50 %
All set-ups
TRUE
0
Uint8
3-6* Ramp 3
3-60
Ramp 3 Type
[0] Linear
All set-ups
TRUE
-
Uint8
3-61
Ramp 3 Ramp up Time
App.Dependent
All set-ups
TRUE
-2
Uint32
3-62
Ramp 3 Ramp down Time
App.Dependent
All set-ups
TRUE
-2
Uint32
3-65
Ramp 3 S-ramp Ratio at Accel. Start
50 %
All set-ups
TRUE
0
Uint8
3-66
Ramp 3 S-ramp Ratio at Accel. End
50 %
All set-ups
TRUE
0
Uint8
3-67
Ramp 3 S-ramp Ratio at Decel. Start
50 %
All set-ups
TRUE
0
Uint8
3-68
Ramp 3 S-ramp Ratio at Decel. End
50 %
All set-ups
TRUE
0
Uint8
3-7* Ramp 4
3-70
Ramp 4 Type
[0] Linear
All set-ups
TRUE
-
Uint8
3-71
Ramp 4 Ramp up Time
App.Dependent
All set-ups
TRUE
-2
Uint32
3-72
Ramp 4 Ramp Down Time
App.Dependent
All set-ups
TRUE
-2
Uint32
3-75
Ramp 4 S-ramp Ratio at Accel. Start
50 %
All set-ups
TRUE
0
Uint8
3-76
Ramp 4 S-ramp Ratio at Accel. End
50 %
All set-ups
TRUE
0
Uint8
3-77
Ramp 4 S-ramp Ratio at Decel. Start
50 %
All set-ups
TRUE
0
Uint8
3-78
Ramp 4 S-ramp Ratio at Decel. End
50 %
All set-ups
TRUE
0
Uint8
Parameter Lists
FC 300 Programming Guide
MG.33.MB.02 - VLT
®
is a registered Danfoss trademark
173