4.1.3 0-** Operation/Display
Par.
No. #
Parameter description
Default value
4-set-up
FC 302
only
Change
during
operation
Conver-
sion index
Type
0-0* Basic Settings
0-01
Language
[0] English
1 set-up
TRUE
-
Uint8
0-02
Motor Speed Unit
[0] RPM
2 set-ups
FALSE
-
Uint8
0-03
Regional Settings
[0] International
2 set-ups
FALSE
-
Uint8
0-04
Operating State at Power-up (Hand)
[1] Forced stop, ref=old
All set-ups
TRUE
-
Uint8
0-09
Performance Monitor
0.0 %
All set-ups
TRUE
-1
Uint16
0-1* Set-up Operations
0-10
Active Set-up
[1] Set-up 1
1 set-up
TRUE
-
Uint8
0-11
Edit Set-up
[1] Set-up 1
All set-ups
TRUE
-
Uint8
0-12
This Set-up Linked to
[0] Not linked
All set-ups
FALSE
-
Uint8
0-13
Readout: Linked Set-ups
0 N/A
All set-ups
FALSE
0
Uint16
0-14
Readout: Edit Set-ups / Channel
0 N/A
All set-ups
TRUE
0
Int32
0-2* LCP Display
0-20
Display Line 1.1 Small
1617
All set-ups
TRUE
-
Uint16
0-21
Display Line 1.2 Small
1614
All set-ups
TRUE
-
Uint16
0-22
Display Line 1.3 Small
1610
All set-ups
TRUE
-
Uint16
0-23
Display Line 2 Large
1613
All set-ups
TRUE
-
Uint16
0-24
Display Line 3 Large
1602
All set-ups
TRUE
-
Uint16
0-25
My Personal Menu
App.Dependent
1 set-up
TRUE
0
Uint16
0-3* LCP Custom Readout
0-30
Unit for User-defined Readout
[0] None
All set-ups
TRUE
-
Uint8
0-31
Min Value of User-defined Readout
0.00 CustomReadoutUnit
All set-ups
TRUE
-2
Int32
0-32
Max Value of User-defined Readout
100.00 CustomRea-
doutUnit
All set-ups
TRUE
-2
Int32
0-37
Display Text 1
0 N/A
1 set-up
TRUE
0
VisStr[25]
0-38
Display Text 2
0 N/A
1 set-up
TRUE
0
VisStr[25]
0-39
Display Text 3
0 N/A
1 set-up
TRUE
0
VisStr[25]
0-4* LCP Keypad
0-40
[Hand on] Key on LCP
null
All set-ups
TRUE
-
Uint8
0-41
[Off] Key on LCP
null
All set-ups
TRUE
-
Uint8
0-42
[Auto on] Key on LCP
null
All set-ups
TRUE
-
Uint8
0-43
[Reset] Key on LCP
null
All set-ups
TRUE
-
Uint8
0-44
[Off/Reset] Key on LCP
null
All set-ups
TRUE
-
Uint8
0-45
[Drive Bypass] Key on LCP
null
All set-ups
TRUE
-
Uint8
0-5* Copy/Save
0-50
LCP Copy
[0] No copy
All set-ups
FALSE
-
Uint8
0-51
Set-up Copy
[0] No copy
All set-ups
FALSE
-
Uint8
0-6* Password
0-60
Main Menu Password
100 N/A
1 set-up
TRUE
0
Int16
0-61
Access to Main Menu w/o Password
[0] Full access
1 set-up
TRUE
-
Uint8
0-65
Quick Menu Password
200 N/A
1 set-up
TRUE
0
Int16
0-66
Access to Quick Menu w/o Password
[0] Full access
1 set-up
TRUE
-
Uint8
0-67
Bus Password Access
0 N/A
All set-ups
TRUE
0
Uint16
Parameter Lists
FC 300 Programming Guide
MG.33.MB.02 - VLT
®
is a registered Danfoss trademark
169
4
4