5.1.13 Motor connection for A2 and A3
Follow these drawings step-by-step for connecting the motor to the adjustable frequency drive.
Figure 5.20: First terminate the motor ground, then place motor U, V and W wires in the plug and tighten them.
Figure 5.21: Mount cable clamp to ensure a 360 degree connection between chassis and shield; ensure that the outer insulation of the motor
cable is removed under the clamp.
5 Electrical installation
VLT
®
AQUA Drive
Instruction Manual
5-14
MG.20.M5.22 - VLT
®
is a registered Danfoss trademark
5