Spyder3 Color Manual
75
DALSA
03-032-20059-01
SRM 0, Auto Mode.
Time Period
Operating Region
Operating Mode
T
0
Immediate Readout state
T
1
Dark Current Dump state
T
2
Immediate Readout state
SRM 2, Immediate Readout Mode.
Time Period
Operating Region
Operating Mode
T
0
Dark Current Dump state
T
1
Immediate Readout state
Dark Current Dump to Immediate Readout (T
INT
< #)
Valid
T
VERT_TRANS
LVAL
EXSYNC
T
DUMP
T
INT
F
DUMP
> DUMP (MAX)
F
Dark Current Dump to Immediate Readout (T
INT
> #)
Valid
EXSYNC
T
DUMP
T
INT
T
VERT_TRANS
LVAL
F
DUMP
> DUMP (MAX)
F
Immediate Readout to Dark Current Dump: Hysteresis Artifacts
SRM 0, Auto Mode.
Time Period
Operating Region
Operating Mode
T
0
Immediate Readout state
Summary of Contents for Spyder3 SC-30-02K80-00-R
Page 24: ...24 Spyder3 Color Manual 03 032 20059 01 DALSA ...
Page 78: ...78 Spyder3 Color Manual 03 032 20059 01 DALSA ...
Page 90: ...90 Spyder3 Color Manual 03 032 20059 01 DALSA ...
Page 98: ...98 Spyder3 Color Manual 03 032 20059 01 DALSA ...
Page 104: ...104 Spyder3 Color Manual 03 032 20059 01 DALSA ...
Page 108: ...108 Spyder3 Color Manual 03 032 20059 01 DALSA ...