70
Spyder3 Color Manual
03-032-20059-01
DALSA
Message
Description
Warning 04: Related
parameters
adjusted>
Parameter was clipped to the current operating range. Use
gcp
to see
value used.
Warning 07:
Coefficient may be
inaccurate A/D
clipping has
occurred>
In the region of interest (ROI) greater than 6.251% single or 1% of
averaged pixel values were zero or saturated.
Warning 08: Greater
than 1% of
coefficients have
been clipped>
A FPN/PRNU has been calculated to be greater than the maximum
allowable 511 (8).
Warning 09: Internal
line rate inconsistent
with readout time>
Message
Description
Error 02:
Unrecognized
command>
Command is not available in the current access level or it is not a valid
command.
Error 03: Incorrect
number of
parameters>
Error 04: Incorrect
parameter value>
This response returned for
·
Alpha received for numeric or vice versa
·
Not an element of the set of possible values. E.g., Baud Rate
·
Outside the range limit
Error 05: Command
unavailable in this
mode>
Command is valid at this level of access, but not effective. Eg line rate
when in smart Exsync mode
Error 06: Timeout>
Command not completed in time. Eg FPN/PRNU calculation when no
external Exsync is present.
Error 07: Camera
settings not saved>
Tried saving camera settings (
rfs
/
rus)
but they cannot be saved.
Error 08: Unable to
calibrate - tap
outside ROI>
Cannot calibrate a tap that is not part of the region of interest.
Error 09: The
camera's
temperature exceeds
the specified
operating range>
Indicates that the camera has shut itself down to prevent damage from
further overheating.
Summary of Contents for Spyder3 SC-30-02K80-00-R
Page 24: ...24 Spyder3 Color Manual 03 032 20059 01 DALSA ...
Page 78: ...78 Spyder3 Color Manual 03 032 20059 01 DALSA ...
Page 90: ...90 Spyder3 Color Manual 03 032 20059 01 DALSA ...
Page 98: ...98 Spyder3 Color Manual 03 032 20059 01 DALSA ...
Page 104: ...104 Spyder3 Color Manual 03 032 20059 01 DALSA ...
Page 108: ...108 Spyder3 Color Manual 03 032 20059 01 DALSA ...