34
Spyder3 Color Manual
03-032-20059-01
DALSA
Mode 6: External Line Rate and Internally Programmable Exposure Time
Figure 13: EXSYNC controls Line Period with Internally controlled Exposure Time
Line Period
Line Period
Readout
Waiting
Exposure Time
CR
Waiting
Readout
Exposure Time
CR
EXSYNC
CR = Charge Reset
Programmable period
using set command
Programmable period
using set command
Mode 7: Internally Programmable Line Rate, Maximum Exposure Time
In this mode, the line rate is set internally with a maximum exposure time.
Figure 14: Mode 7 Camera Timing
Line Period
Line Period
Exposure Time
Exposure Time
Readout
Readout
EXSYNC falling edge
ignored during
readout
EXSYNC falling edge
ignored during
readout
Internal SYNC set
using the ssf command
Mode 8: Maximum Line Rate, Programmable Exposure Time
In this mode, the exposure time is set internally with a maximum line rate.
Figure 15: Mode 8 Timing
Programmable Period
Frame Period
Readout
CR Exposure Time
CR=Charge Reset
Frame Period
Programmable Period
CR Exposure Time
Readout
Summary of Contents for Spyder3 SC-30-02K80-00-R