Spyder3 Color Manual
33
DALSA
03-032-20059-01
to the maximum time (line period – line transfer time – pixel reset time) for that line
rate when a new line rate requiring reduced exposure time is entered.
When setting the exposure time (using the
set
command), line time will be
increased, if necessary, to accommodate the exposure time. Under this condition, the
line time will equal the exposure time + line transfer time.
Example 1: Exposure Time Less than Line Period
Readout
Waiting
Exposure Time
Readout
Waiting CR
Exposure Time
Programmable Period (set command)
Programmable Period
CR
Line Period
Line Period
Programmable Period (ssf command)
Programmable Period
CR = Charge Reset
Mode 3: External Trigger with Maximum Exposure
Line rate is set by the period of the external trigger pulses. The falling edge of the external
trigger marks the beginning of the exposure.
Example 2: Line Rate is set by External Trigger Pulses.
Line Period
Line Period
Readout
Readout
Exposure Time
Exposure Time
EXSYNC
Falling edge ignored
during readout
Falling edge ignored
during readout
Mode 4: Smart EXSYNC, External Line Rate and Exposure Time
In this mode, EXSYNC sets both the line period and the exposure time. The rising edge of
EXSYNC marks the beginning of the exposure and the falling edge initiates readout.
Example 3: Trigger Period is Repetitive and Greater than Read Out Time.
Line Period
Line Period
Readout
Waiting
Exposure Time
CR
Waiting
Readout
Exposure Time
CR
EXSYNC
CR = Charge Reset
EXSYNC falling edge
ignored during readout
EXSYNC falling edge
ignored during readout
Summary of Contents for Spyder3 SC-30-02K80-00-R
Page 24: ...24 Spyder3 Color Manual 03 032 20059 01 DALSA ...
Page 78: ...78 Spyder3 Color Manual 03 032 20059 01 DALSA ...
Page 90: ...90 Spyder3 Color Manual 03 032 20059 01 DALSA ...
Page 98: ...98 Spyder3 Color Manual 03 032 20059 01 DALSA ...
Page 104: ...104 Spyder3 Color Manual 03 032 20059 01 DALSA ...
Page 108: ...108 Spyder3 Color Manual 03 032 20059 01 DALSA ...