Purpose:
Sets the camera‘s line rate in Hz. Camera must be operating in
exposure mode 2 or 7.
Syntax:
ssf
f
Syntax Elements:
i
Desired line rate in Hz. Allowable values are:
2k 2 tap:
300 - 18000
Hz
4k 2 tap:
300- 9000
Hz
Notes:
To read the current line frequency, use the command
gcp
or
get
ssf
.
If you enter an invalid line rate frequency, an error message is
returned.
Related Commands:
sem, set
Example:
ssf 10000
i
Applies to Modes 2 and
7