Parameter Min
Max
UM
Description
DA28
0.00
99.90
bar
External air - Opening limitation - Summer oper. - Max cond. press. thre
-
shold for activation
DA29
0.00
99.90
bar
External air - Opening limitation - Summer oper. - Max cond. press. diff. for
activation
DA30
0.00
99.90
bar
External air - Opening limitation - Summer oper. - Max evap. press. thre
-
shold for activation
DA31
0.00
99.90
bar
External air - Opening limitation - Summer oper. - Max evap. press. diff. for
activation
DA32
0.00
99.90
bar
External air - Opening limitation - Winter oper. - Min cond. press. threshold
for activation
DA33
0.00
99.90
bar
External air - Opening limitation - Winter oper. - Min cond. press. diff. for
activation
DA34
0.00
99.90
bar
External air - Opening limitation - Winter oper. - Min evap. press. threshold
for activation
DA35
0.00
99.90
bar
External air - Opening limitation - Winter oper. - Min evap. press. diff. for
activation
DA36
0
60
%
External air - Opening limitation - Min opening for cond. press.
DA37
0
100
%
External air - Opening limitation - Max opening for cond. press.
DA38
0
60
%
External air - Opening limitation - Min opening for evap. press.
DA39
0
100
%
External air - Opening limitation - Max opening for evap. press.
DA40
0.00
50.00
bar
External air - Opening limitation - Deactivation diff. for cond. press.
DA41
0.00
30.00
bar
External air - Opening limitation - Deactivation diff. for evap. press.
DA43
0.0
50.0
°C
External air - Opening reduction for external air temperature - Summer tem
-
perature threshold
DA44
-20.0
16.0
°C
External air - Opening reduction for external air temperature - Winter tempe
-
rature threshold
DA45
0
100
%
External air - Opening reduction for external air temperature - Min opening
DA46
0
300
s
External air - Opening reduction for external air temperature - Activation
delay
DA48
0
100
%
External air - Dehumidification - Min opening
DA52
0
3
-
External air - Start up - Configuration
DA53
0
1
-
External air - Start up - Thermoregulation
DA54
0
999
min
External air - Start up - Wash duration
DA55
0
999
min
External air - Start up - Recirculation duration
DA61
0
10000
-
External air - PID - Adaptive control - Kp
DA62
0
10000
-
External air - PID - Adaptive control - Ki
DA63
0
10000
-
External air - PID - Adaptive control - Kd
DA67
0.0
25.0
°C
External air - PID - Adaptive control - Dead band
DA69
0
2
-
External air - PID - Adaptive control - Dead band position
DA91
0
100
%
Recirculation air - Min opening
DA92
10
100
%
Recirculation air - Max opening
3 Software functions
Summary of Contents for UATYA-B
Page 1: ...Operation manual Daikin R32 Rooftops UATYA B ESIE21 02...
Page 4: ...4 Service manual Daikin R32 Rooftops UATYA B ESIE21 02 2021 03 Page intentionally blank...
Page 122: ...122 Service manual Daikin R32 Rooftops UATYA B ESIE21 02 2021 03 Page intentionally blank...
Page 123: ...123 Service manual Daikin R32 Rooftops UATYA B ESIE21 02 2021 03 Page intentionally blank...
Page 124: ...124 Service manual Daikin R32 Rooftops UATYA B ESIE21 02 2021 03 Page intentionally blank...
Page 125: ...125 Service manual Daikin R32 Rooftops UATYA B ESIE21 02 2021 03 Page intentionally blank...