SiUS28-902_a
Field Setting
Test Operation
62
: ON
: OFF
l
: Blink
Setting
No.
Setting
contents
Setting No. indication
Setting No. indication
Setting
contents
Setting contents indication (Initial setting)
H1P H2P H3P H4P H5P H6P H7P H1P H2P H3P H4P H5P H6P H7P
H1P H2P H3P H4P H5P H6P H7P
12
External
low noise /
Demand
setting
NO
(Factory
set)
l
YES
l
22
Night-time
low noise
setting
OFF
(Factory
setting)
Mode 1
l
Mode 2
l
Mode 3
l
l
26
Night-time
low noise
start setting
PM 8:00
l
PM 10:00
(Factory
setting)
l
PM 0:00
l
27
Night-time
low noise
end setting
AM 6:00
l
AM 7:00
l
AM 8:00
(Factory
setting)
l
29
Capacity
precedence
setting
Low noise
precedence
(Factory
setting)
l
Capacity
precedence
l
30
Demand
setting 1
60 % of
rated power
consumption
l
70 % of
rated power
consumption
(Factory
setting)
l
80 % of
rated power
consumption
l
32
Normal
demand
setting
OFF
(Factory
setting)
l
ON
l
Setting mode indication section
Setting No. indication section
Set contents indication section
Summary of Contents for SkyAir FCQ18PVJU
Page 1: ...Split System Air Conditioners SkyAir Inverter R 410A Heat Pump 60Hz P Series SiUS28 902_a...
Page 44: ...Other Control SiUS28 902_a 37 Function...
Page 81: ...SiUS28 902_a Troubleshooting by Remote Controller Troubleshooting 74...
Page 185: ...SiUS28 902 Precautions for New Refrigerant R 410A Precautions for New Refrigerant R 410A 178...