Field Setting
SiUS28-902_a
57
Test Operation
No.
Setting item
Description
5
Indoor unit forced
fan H
Allows forced operation of indoor unit fan while unit is
stopped. (H tap)
6
Indoor unit forced
operation
Allows forced operation of indoor unit.
8
Te setting
Target evaporation temperature for cooling
9
Tc setting
Target condensation temperature for heating
10
Defrost changeover
setting
Changes the temperature condition for defrost and sets to
quick defrost or slow defrost.
12
External low noise
setting / Demand
setting
Reception of external low noise or demand signal
21
Refrigerant
recovery /
vacuuming mode
setting
Sets to refrigerant recovery / vacuuming mode.
22
Night-time low
noise setting
Sets automatic nighttime low noise operation in a simple
way.
The operating time is based on “Starting set” and “Ending
set”.
26
Night-time low
noise operation
start setting
Sets starting time of nighttime low noise operation.
(Night-time low noise setting is also required.)
27
Night-time low
noise operation
end setting
Sets ending time of nighttime low noise operation.
(Night-time low noise setting is also required.)
29
Capacity
precedence setting
If the capacity control is required, the low noise control is
automatically activated by this setting.
30
Demand setting 1
Changes target value of power consumption when
demand control 1 is input.
32
Normal demand
setting
Normally enables demand control 1 without external
input. Effective to prevent a problem that circuit breaker
of of small capacity is shut down due to large load.
b. “Settin
g
mode 2”
<Selection of settin
g
items>
<Selection of settin
g
conditions>
P
u
sh and hold the MODE
bu
tton
(BS1) for 5 seconds and set to
“Setting mode 2”.
P
u
sh the SET
bu
tton (BS2) and set
the LED display to a setting item
sho
w
n in the ta
b
le on the right.
¯
P
u
sh the RETUR
N
bu
tton (BS3) and
decide on the item. (The present
setting condition is
b
linking.)
P
u
sh the SET
bu
tton (BS2) and set
to the setting condition yo
u
w
ant.
¯
P
u
sh the RETUR
N
bu
tton (BS3) and
decide the condition.
P
u
sh the RETUR
N
bu
tton (BS3) and
set to the initial stat
u
s of “Setting
mode 2”.
*
If yo
u
b
ecome
u
ns
u
re of ho
w
to
proceed, p
u
sh the MODE
bu
tton
(BS1) and ret
u
rn to setting mode 1.
Summary of Contents for SkyAir FCQ18PVJU
Page 1: ...Split System Air Conditioners SkyAir Inverter R 410A Heat Pump 60Hz P Series SiUS28 902_a...
Page 44: ...Other Control SiUS28 902_a 37 Function...
Page 81: ...SiUS28 902_a Troubleshooting by Remote Controller Troubleshooting 74...
Page 185: ...SiUS28 902 Precautions for New Refrigerant R 410A Precautions for New Refrigerant R 410A 178...