![background image](http://html1.mh-extra.com/html/daikin/ftks20d3vmw/ftks20d3vmw_service-manual_4060508153.webp)
Instruction
SiENBE12-713
142
System Configuration
2.1.8 OUTDOOR UNIT QUIET Operation
NOTES
OUTDOOR UNIT QUIET operation lowers the noise level of the outdoor
unit by changing the frequency and fan speed on the outdoor unit. This
function is convenient during night.
"
To start OUTDOOR UNIT QUIET operation
1. Press “QUIET button”.
•
“
” is displayed on the LCD.
"
To cancel OUTDOOR UNIT QUIET operation
2. Press “QUIET button” again.
•
“
” disappears from the LCD.
"
Note on OUTDOOR UNIT QUIET operation
•
If using a multi system, this function will work only when the OUTDOOR UNIT QUIET operation is set on all operated
indoor units.
However, if using priority-room setting, see “Note for multi system”.
•
This function is available in COOL, HEAT, and AUTO modes.
(This is not available in FAN and DRY mode.)
•
POWERFUL operation and OUTDOOR UNIT QUIET operation cannot be used at the same time.
Priority is given to the function of wichever button is pressed last.
•
If operation is stopped using the remote control or the main unit ON/OFF switch when using OUTDOOR UNIT QUIET
operation, “
” will remain on the remote control display.
TIMER
ON
CANCEL
OFF
1, 2
Summary of Contents for FTKS20D3VMW
Page 11: ...Introduction SiENBE12 713 x...
Page 47: ...Specifications SiENBE12 713 36 Specifications...
Page 113: ...Control Specification SiENBE12 713 102 Function and Control...
Page 235: ...Instruction SiENBE12 713 224 System Configuration...
Page 297: ...Check SiENBE12 713 286 Service Diagnosis...
Page 316: ...SiENBE12 713 Outdoor Unit Removal Procedure 305 Step Procedure Points...