![background image](http://html1.mh-extra.com/html/daikin/ftks20d3vmw/ftks20d3vmw_service-manual_4060508051.webp)
Printed Circuit Board Connector Wiring Diagram
SiENBE12-713
40
Printed Circuit Board Connector Wiring Diagram
1.1.2 FTK(X)S20~35C
Connectors
PCB(1) (Control PCB)
PCB(2) (Signal Receiver PCB)
PCB(3) (INTELLIGENT EYE sensor PCB)
Note:
Other designations
PCB(1) (Control PCB)
PCB(2) (Signal Receiver PCB)
1) S1
Connector for fan motor
2) S6
Connector for swing motor (Horizontal Flap)
3) S7
Connector for fan motor
4) S21
Connector for centralized control to 5 rooms
5) S26
Connector for signal receiver PCB
6) S27
Connector for control PCB
7) S32
Connector for heat exchanger thermistor
8) S35
Connector for INTELLIGENT EYE Sensor PCB
1) S36
Connector for control PCB
1) V1
Varistor
2) JA
Address setting jumper
JB
Fan speed setting when compressor is OFF on thermostat
JC
Power failure recovery function
∗
Refer to page 321 for more detail.
3) SW7
Forced operation ON/OFF switch
4) LED1
LED for operation (green)
5) LED2
LED for timer (yellow)
6) LED3
LED for HOME LEAVE operation (red)
7) LED A
LED for service monitor (green)
8) FU1
Fuse (3.15A)
9) RTH1
Room temperature thermistor
Summary of Contents for FTKS20D3VMW
Page 11: ...Introduction SiENBE12 713 x...
Page 47: ...Specifications SiENBE12 713 36 Specifications...
Page 113: ...Control Specification SiENBE12 713 102 Function and Control...
Page 235: ...Instruction SiENBE12 713 224 System Configuration...
Page 297: ...Check SiENBE12 713 286 Service Diagnosis...
Page 316: ...SiENBE12 713 Outdoor Unit Removal Procedure 305 Step Procedure Points...