![background image](http://html1.mh-extra.com/html/daikin/ftks20d3vmw/ftks20d3vmw_service-manual_4060508313.webp)
Outdoor Unit
SiENBE12-713
302
Removal Procedure
4
Undo the 3 hooks on
the reactor side and
slide the control PCB.
5
Undo the relay harness
for compressor from the
hook.
6
Lift up the control PCB
to remove.
"
In working, be careful not to
break the control PCB with
the excessive force because
the PCB and the radiation fin
are adhered to one another.
"
When assembling, make
sure to use the silicon
material.
"
Silicon material
Part No.: 1172698
7
Each wire harness.
Step
Procedure
Points
Compre
ss
or rel
a
y h
a
rne
ss
E
a
rth wire