![background image](http://html1.mh-extra.com/html/daikin/ftks20d3vmw/ftks20d3vmw_service-manual_4060508308.webp)
SiENBE12-713
Outdoor Unit
Removal Procedure
297
14
The figure shows the
arrangement of the wire
harness under the
electrical box.
15
Undo the wire clip for
the thermistor lead wire.
3. Remove the electrical box
1
Loosen the 2 screws of
the earth terminal.
4. Disconnect the power
supply connecting wires
★
Illustrations are for 3 room
model.
1
Loosen the screws on
the terminal board and
disconnect the wires of
A, B, C, and D port.
Step
Procedure
Points
S
ervice PCB
Power
su
pply
termin
a
l
b
o
a
rd
(L) -Bl
a
ck
(N) - Whit
Wiring fixt
u
re
Summary of Contents for FTKS20D3VMW
Page 11: ...Introduction SiENBE12 713 x...
Page 47: ...Specifications SiENBE12 713 36 Specifications...
Page 113: ...Control Specification SiENBE12 713 102 Function and Control...
Page 235: ...Instruction SiENBE12 713 224 System Configuration...
Page 297: ...Check SiENBE12 713 286 Service Diagnosis...
Page 316: ...SiENBE12 713 Outdoor Unit Removal Procedure 305 Step Procedure Points...