The system does not start when the display shows
“
” (UNDER CENTRALIZED CONTROL) and it
flashes for few seconds after pressing an operation
button.
This is because the system is under centralized control.
Flashes on the display indicates that the system cannot be
controlled by the remote control.
•
The system does not start immediately after the power
supply is turned on.
Wait one minute until the micro computer is prepared for
operation.
•
The outdoor unit is stopped.
This is because the room temperature has reached the set
temperature. The indoor unit switches to fan operation.
II.
When “
” (UNDER CENTRALIZED
CONTROL) is displayed and operation is
defferent from the remote control display.
This is because operating mode is controlled by a micro
computer, as shown below, depending on the operating
mode of the other connected indoor units when using in a
multi system.
•
If the operating mode does not match that of the other
indoor units which are already running, the indoor unit
goes into standby mode (the fan stops and the air flow
flaps become horizontal).
The unit will go into the above mode if either cooling, dry,
or fan operation mode are set together with heating mode.
NOTE
•
Normally, the operation mode in the room where the unit is
first run is given priority, but the following situations are
exceptions, so please keep this in mind.
a. If the operation mode of the first room is FAN Mode,
then using Heating Mode in any room after this will give
priority to heating. In this situation, the air conditioner
running in FAN Mode wil go on standby.
b. With the Priority Room Setting active.
Contact your Daikin dealer for the operation that
corresponds to your system.
•
If the total capacity of operating indoor units exceeds
the limit, the indoor unit will assume the STANDBY
state (FAN and AIR FLOW DIRECTION will be left as
set). (This only applies to cooling only type.)
•
If another indoor unit commences a HEATING
operation after this indoor unit is running in COOLING
mode, this indoor unit may switch to DRY operation
(fan on low, air flow flap set at horizontal).
•
III. The fan speed is different from the setting.
•
Pressing the fan speed control button does not
change the fan speed.
When the room temperature reaches the set temperature
in heating mode, the power supply from the outdoor unit is
stopped and the indoor unit will operate on the low fan
setting. (If using the multi system, the fan will alternate
between off and low.)
This is to prevent the cool air from being blown directly
onto anyone in the room.
IV. Air blow direction is not as specified.
•
Actual air blow direction is not as shown on the
remote control.
•
Automatic swing setting does not work.
Refer to “AIR FLOW DIRECTION ADJUST.”
V.
White mist comes out of a unit
•
When humidity is high during cooling operation (In
oily of dusty places)
If the inside of an indoor unit is extremely contaminated,
the temperature distribution inside a room becomes
uneven. It is necessary to clean the inside of the indoor
unit. Ask your Daikin dealer for details on cleaning the unit.
This operation requires a qualified service person.
•
When the system is changed over to HEATING
OPERATION after DEFROST OPERATION.
Moisture generated by DEFROST becomes steam and
exists.
VI. Noise of air conditioners
A ringing sound after the unit is started.
This sound is generated by the temperature regulator
working.
It will quiet down after about a minute.
•
A continuous flow “Shuh” sound is heard when the
system is in COOLING or DEFROST OPERATION.
This is the sound of refrigerant gas flowing through both
indoor and outdoor units.
•
A “Shuh” sound which is heard at the start or
immediately after the stop of operation or which is
heard at the start or immediately after the stop of
DEFROST OPERATION.
This is the noise of refrigerant caused by flow stop and
flow change.
•
A continuous flowing sound “Shah” or a trickling
sound “Jyuru Jyuru” are heard when the system is in
COOLING OPERATION or at a stop.
The noise is heard when the drain pump is in operation.
•
A “Pishi-Pishi” squeaking sound is heard when the
system is in operation or after the stop of operation.
Expansion and contraction of plastic parts caused by
temperature change makes this noise.
VII.Dust from the units
•
Dust may blow out from the unit after starting
operation from long resting time.
Dust absorbed by the unit blows out.
VIII.The units give off odors
The unit absorbs the smell of rooms, furniture, cigarettes,
etc., and then emits them.
IX. The liquid crystal of the remote control show “
88
”
•
It happens immediately after the main power supply
switch is turned on.
This shows that the remote control is in normal condition.
This continues temporary.
Summary of Contents for FTKS20D3VMW
Page 11: ...Introduction SiENBE12 713 x...
Page 47: ...Specifications SiENBE12 713 36 Specifications...
Page 113: ...Control Specification SiENBE12 713 102 Function and Control...
Page 235: ...Instruction SiENBE12 713 224 System Configuration...
Page 297: ...Check SiENBE12 713 286 Service Diagnosis...
Page 316: ...SiENBE12 713 Outdoor Unit Removal Procedure 305 Step Procedure Points...