5
|
Application guidelines
Installer reference guide
23
ERLA EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596821-1A – 2020.05
5 Application guidelines
In this chapter
5.1 Overview: Application guidelines
The purpose of the application guidelines is to give a glance of the possibilities of
the heat pump system.
NOTICE
▪
The illustrations in the application guidelines are meant for reference only, and
are NOT to be used as detailed hydraulic diagrams. The detailed hydraulic
dimensioning and balancing are NOT shown, and are the responsibility of the
installer.
▪
For more information about the configuration settings to optimize heat pump
operation, see
96].
This chapter contains application guidelines for:
▪
Setting up the space heating system
▪
Setting up the domestic hot water tank
▪
Setting up the energy metering
▪
Setting up the power consumption control
▪
Setting up an external temperature sensor
5.2 Setting up the space heating system
The heat pump system supplies leaving water to heat emitters in one or more
rooms.
Because the system offers a wide flexibility to control the temperature in each
room, you need to answer the following questions first:
▪
How many rooms are heated by the heat pump system?
Summary of Contents for ERLA03DAV3