8
|
Electrical installation
Installer reference guide
85
ERLA EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596821-1A – 2020.05
B
A
B
X5M
11 12
P2 P1
a
Main user interface: Required for operation. Delivered with the unit as accessory.
b
Optional user interface
3
Insert a screwdriver into the slots underneath the user interface and carefully
separate the faceplate from the wallplate. The PCB is mounted in the
faceplate of the user interface. Be careful NOT to damage it.
4
Fix the wallplate of the user interface to the wall.
5
Connect as shown in A, B, C or D:
A
From the rear
b
a
PCB
1×
B
From the left
a
PCB
b
1×
C
From the top
a
b
PCB
b
1×
D
From the top centre
a
PCB
b
b
1×
a
Notch this part for the wiring to pass through with nippers etc.
b
Secure the wiring to the front part of the casing using the wiring
retainer and clamp.
6
Reinstall the faceplate onto the wallplate. Be careful NOT to pinch the wiring
when attaching the frontplate to the unit.
8.3.4 To connect the shut-off valve
Wires: 2×0.75 mm²
Maximum running current: 100 mA
230 V AC supplied by PCB
Summary of Contents for ERLA03DAV3
Page 1: ...Installer reference guide Daikin Altherma 3 R F ERLA03DAV3 EHFZ03S18DJ3V...
Page 182: ...1 7 Field settings table 6 8 2 ID9E51 Applicable units EHFZ03S18DJ3V Notes 4P596829 1 2019 10...
Page 189: ......
Page 190: ......
Page 191: ......
Page 192: ...4P596821 1A 2020 05 Copyright 2019 Daikin Verantwortung f r Energie und Umwelt...