Electrical installation
Installer reference guide
91
ERLA EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596821-1A – 2020.05
3
Connect the changeover to external heat source cable to the appropriate
terminals as shown in the illustration below.
A
X1
X2
L
N
B
A
B
A4P
X2M
X1
a
X2
a
Installation of EKRP1HBAA is required.
4
Fix the cable with cable ties to the cable tie mountings.
8.3.10 To connect the power consumption digital inputs
Wires: 2 (per input signal)×0.75 mm²
Power limitation digital inputs: 12 V DC / 12 mA detection (voltage
supplied by PCB)
[A.6.3]
Pwr consumpt. control
1
Open the service cover. See
"6.2.2 To open the outdoor unit"
2
Open the following (see
"6.2.4 To open the indoor unit"
1
Top panel
1
2
3
2
Upper front panel
3
Upper switch box cover
3
Connect the power consumption digital inputs cable to the appropriate
terminals as shown in the illustration below.