![background image](http://html1.mh-extra.com/html/daikin/erla03dav3/erla03dav3_installers-reference-manual_4270620087.webp)
8
|
Electrical installation
Installer reference guide
87
ERLA EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596821-1A – 2020.05
INFORMATION
In case of an electricity meter with transistor output, check the polarity. The positive
polarity MUST be connected to X5M/6 and X5M/4; the negative polarity to X5M/5
and X5M/3.
1
Open the service cover. See
"6.2.2 To open the outdoor unit"
2
Open the following (see
"6.2.4 To open the indoor unit"
1
Top panel
1
2
3
2
Upper front panel
3
Upper switch box cover
3
Connect the electricity meters cable to the appropriate terminals as shown in
the illustration below.
A
6
5
4
3
S3S S2S
B
A
B
X5M
3 4 5 6
4
Fix the cable with cable ties to the cable tie mountings.
8.3.6 To connect the domestic hot water pump
Wires: (2+GND)×0.75 mm²
DHW pump output. Maximum load: 2 A (inrush), 230 V AC, 1 A
(continuous)
[A.2.2]
Options
> [A.2.2.A]
DHW pump
[7.3]
Set schedules
> [7.3.7]
DHW pump
1
Open the service cover. See
"6.2.2 To open the outdoor unit"
2
Open the following (see