![background image](http://html1.mh-extra.com/html/daikin/erla03dav3/erla03dav3_installers-reference-manual_4270620117.webp)
9
|
Configuration
Installer reference guide
117
ERLA EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596821-1A – 2020.05
NOTICE
When adjusting the room temperature ranges, all desired room temperatures are
also adjusted to guarantee they are between the limits.
#
Code
Description
Room temp. range
[A.3.2.1.2]
[3-06]
Maximum temp (heating)
18°C~30°C
[A.3.2.1.1]
[3-07]
Minimum temp (heating)
12°C~30°C
Room temperature step
ONLY applicable in room thermostat control and when the temperature is
displayed in °C.
#
Code
Description
[A.3.2.4]
N/A
Room temp. step
▪
1°C. The desired room temperature on the user
interface is settable per 1°C.
▪
0.5°C. The desired room temperature on the
user interface is settable per 0.5°C. The actual
room temperature is displayed with an
accuracy of 0.1°C.
Room temperature hysteresis
ONLY applicable in case of room thermostat control. The hysteresis band around
the desired room temperature is settable. It is recommended NOT to change the
room temperature hysteresis as it is set for an optimal use of the system.
[9-0C]
a
b
c
d
a
Room temperature
b
Actual room temperature
c
Desired room temperature
d
Time
#
Code
Description
N/A
[9-0C]
1°C~6°C
Room temperature offset
ONLY applicable in case of room thermostat control. You can calibrate the room
temperature sensor. It is possible to give an offset to the room thermistor value
measured by the user interface. The settings can be used to compensate for
situations where the user interface cannot be installed on the ideal installation
location.
#
Code
Description
Room temp. offset
: Offset on the actual room temperature measured on the
user interface sensor.
[A.3.2.2]
[2-0A]
–5°C~5°C, step 0.5°C
Summary of Contents for ERLA03DAV3
Page 1: ...Installer reference guide Daikin Altherma 3 R F ERLA03DAV3 EHFZ03S18DJ3V...
Page 182: ...1 7 Field settings table 6 8 2 ID9E51 Applicable units EHFZ03S18DJ3V Notes 4P596829 1 2019 10...
Page 189: ......
Page 190: ......
Page 191: ......
Page 192: ...4P596821 1A 2020 05 Copyright 2019 Daikin Verantwortung f r Energie und Umwelt...