SiEN18-621
Instruction
System Configuration
243
Refer to figure 1 on page [1]
•
Operating procedure varies with heat pump type and
cooling only type. Contact your Daikin dealer to confirm
your system type.
•
to protect the unit, turn on the main power switch 6 hours
before operation.
•
If the main power supply is turned off during operation,
operation will restart automatically after the power turns
back on again.
Operate in the following order.
Operation mode selector
Press OPERATION MODE SELECTOR button several
times and select the OPERATION MODE of your choice as
follows.
"
COOLING OPERATION............................“
”
"
HEATING OPERATION.......................... “ ”
"
AUTOMATIC OPERATION.....................“ ”
•
In this operation mode, COOL/HEAT changeover is
automatically conducted
"
FAN OPERATION...................................“
”
"
DRY OPERATION ..................................“ ”
•
The function of this program is to decrease the
humidity in your room with the minimum temperature
decrease.
•
Micro computer automatically determines
TEMPERATURE and FAN SPEED.
•
This system does not go into operation if the room
temperature is below 16°C.
Refer to figure 3 on page [1]
•
For cooling only type, “COOLING”, “FAN” and “DRY”
operation are able to select.
ON/OFF
Press ON/OFF button
OPERATION lamp lights up or goes off and the system starts
or stops OPERATION.
[EXPLANATION OF HEATING OPERATION]
DEFROST OPERATION
•
As the frost on the coil of an outdoor unit increases,
heating effect decreases and the system goes into
DEFROST OPERATION.
•
The indoor unit fan stops and the remote control display
shows “
”.
•
After 6 to 8 minutes (maximum 10 minutes) of DEFROST
OPERATION, the system returns to HEATING OPERATION.
Regarding outside air temperature and heating capacity
•
The heating capacity of the air conditioner declines as the
outside air temperature falls.
In such a case, use the air conditioner in combination with
other heating systems.
•
A warm air circulation system is employed, and therefore it
takes some time until the entire room is warmed up after
the start of operation.
•
An indoor fan runs to discharge a gentle wind
automatically until the temperature inside the air
conditioner reaches a certain level. At this time, the remote
control displays “
”. Leave it as it stands and wait
for a while.
•
When the warm air stays under the ceiling and your feet
are cold, we recommend that you use a circulator (a fan to
circulate the air inside the room). For details, consult your
dealer.
For programming TEMPERATURE, FAN SPEED and AIR
FLOW DIRECTION, follow the procedure shown below.
Temperature setting
Press TEMPERATURE SETTING button and program the
setting temperature.
Each time this button is pressed, setting
temperature rises 1°C
Each time this button is pressed, setting
temperature lowers 1°C
•
The setting is impossible for fan operation
NOTE
•
The setting temperature range of the remote control is
16°C to 32°C.
Fan speed control
Press FAN SPEED CONTROL button.
High or Low fan speed can be selected.
Micro computer may sometimes control the fan speed in order
to protect the unit.
Air flow direction adjust
•
There are 2 ways of adjusting the air discharge angle.
1. A. Up and down adjustment
2. B. Left and right direction
6. Operation procedure
Cooling, heating, automatic, fan, and program dry
operation
1
2
Adjustment
Summary of Contents for BPMKS967B2B
Page 1: ...SiENBE18 621 E Series Service Manual Applied Models Super Multi Plus Heat Pump...
Page 12: ...SiENBE18 621 List of Functions 1 Part 1 List of Functions 1 List of Functions 2...
Page 19: ...List of Functions SiENBE18 621 8 List of Functions...
Page 33: ...Specifications SiENBE18 621 22 Specifications...
Page 69: ...Refrigerant Flow for Each Operation Mode SiENBE18 621 58 Refrigerant Circuit...
Page 121: ...Indoor Unit SkyAir Models SiENBE18 621 110 Function...
Page 169: ...Instruction SiENBE18 621 158 System Configuration FTXS 20 25 35C Indoor Unit...
Page 371: ...Method of Replacing The Inverter s Power Transistors Modules SiENBE18 621 360 Troubleshooting...
Page 393: ...SiENBE18 621 vi Index...