SiENBE18-621
Instruction
System Configuration
175
NOTE
"
To set the clock
1. Press “CLOCK button”.
0:00
is displayed.
blinks.
2. Press “TIMER setting button” to set the
clock to the present time.
Holding down “
” or “
” button rapidly
increases or decreases the time display.
3. Press “CLOCK button”.
:
blinks.
"
Turn the breaker ON
•
Turning ON the breaker opens the flap, then
closes it again. (This is a normal procedure.)
"
Tips for saving energy
•
Be careful not to cool (heat) the room too much.
Keeping the temperature setting at a moderate level helps to save energy.
•
Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors increases the cooling (heating) effect.
•
Clogged air filters cause inefficient operation and waste energy. Clean them once in about every two weeks.
"
Please note
•
The air conditioner always consumes 15-35 watts of electricity even while it is not operating.
•
If you are not going to use the air conditioner for a long period, for example in spring or autumn, turn the breaker OFF.
•
Use the air conditioner in the following conditions.
•
Operation outside this humidity or temperature range may cause a safety device to disable the system.
Recommended temperature setting
For cooling:26°C – 28°C
For heating:20°C – 24°C
Mode
Operating conditions
If operation is continued out of this range
COOL
Outdoor temperature
<2MK(X)S40 10 to 46°C
<2MXS52> –10 to 46°C
<3/4/5MK(X)S> –10 to 46°Cá
<RK(X)S –10> to 46°C
Indoor temperature: 18 to 32°C
Indoor humidity: 80% max.
• A safety device may work to stop the operation.
(In multi system, it may work to stop the
operation of the outdoor unit only.)
• Condensation may occur on the indoor unit and
drip.
HEAT
Outdoor temperature
<2MXS40> –10 to 15.5°C
<2MXS52> –15 to 15.5°C
<3/4/5MXS> –15 to 15.5°C
<RXS20/25/35> –15 to 20°C
<RXS50> –15 to 18°C
Indoor temperature: 18 to 32°C
• A safety device may work to stop the operation.
DRY
Outdoor temperature:
<2MK(X)S40W 10 to 46°C
<2MXS52W –10 to 46°C
<3/4/5MK(X)SW –10 to 46°C
<RK(X)S> –10 to 46°C
Indoor temperature: 18 to 32°C
Indoor humidity: 80% max.
• A safety device may work to stop the operation.
• Condensation may occur on the indoor unit and
drip.
Summary of Contents for BPMKS967B2B
Page 1: ...SiENBE18 621 E Series Service Manual Applied Models Super Multi Plus Heat Pump...
Page 12: ...SiENBE18 621 List of Functions 1 Part 1 List of Functions 1 List of Functions 2...
Page 19: ...List of Functions SiENBE18 621 8 List of Functions...
Page 33: ...Specifications SiENBE18 621 22 Specifications...
Page 69: ...Refrigerant Flow for Each Operation Mode SiENBE18 621 58 Refrigerant Circuit...
Page 121: ...Indoor Unit SkyAir Models SiENBE18 621 110 Function...
Page 169: ...Instruction SiENBE18 621 158 System Configuration FTXS 20 25 35C Indoor Unit...
Page 371: ...Method of Replacing The Inverter s Power Transistors Modules SiENBE18 621 360 Troubleshooting...
Page 393: ...SiENBE18 621 vi Index...