OC
Blockage due to motor
overload
-
One attempt every 10 minutes for a total of
6 attempts.
-
One attempt every hour for a total of 24 at
-
tempts.
-
One attempt every 24 hours for a total of 30
attempts.
7 - RESET AND FACTORY SETTINGS
7.1 - General system reset
To reset the system, hold down the 4 keys simultaneously for 2 sec. This operation is the
same as disconnecting the power, waiting for it to close down completely and supplying
power again. The reset does not delete the settings saved by the user.
7.2 - Factory settings
The device leaves the factory with a series of preset parameters which may be changed
according to the user’s requirements. Each change of the settings is automatically saved
in the memory and, if desired, it is always possible to restore the factory conditions (see
Restoring the factory settings par par 7.3 - Restoring the factory settings).
7.3 - Restoring the factory settings
To restore the factory values, switch off the device, wait until the display has switched off
completely, press and hold down the “SET” and “
˄
” keys and turn on the power; release
the two keys only when the letters “EE” appear. This restores the factory settings (a mes
-
sage and a rereading on EEPROM of the factory settings permanently saved in the FLASH
memory). Once all the parameters have been set, the device returns to normal operation.
NOTE: Once the factory values have been restored it will be necessary to reset all the
parameters that characterise the system (gains, setpoint pressure, etc.) as at the first in
-
stallation.
Factory settings
Identifying code
Description
Value
e.sybox mini
³
Installation Memo
Table 9: Self-reset of blockages
BK
Display brightness
80%
TK
Backlight lighting T
2 min
LA
Language
ENG
SP
Setpoint pressure [bar]
2,7
RI
Revs per minute in manual mode
[rpm]
3200
OD
Type of plant
1 (Rigid)
RP
Pressure decrease to restart [bar]
0,3
MS
Measuring system
0 (International)*
EK
Low pressure function on suction
2
PK
Low pressure threshold on
suction [bar]
0,5
TB
Blockage time for water lack [s]
15
T1
Low pr. delay [s]
8
T2
Delay in switching off [s]
30
GP
Proportional gain
coefficient
0,5
GI
Integral gain coefficient
1,2
RM
Maximum speed
7000
AE
Anti-blocking function
1(Enable)
AF
Antifreeze
0
PW
Change Password
0 (Disabled)
AY
Anticycling Function AY
2 (SMART)
*: for products intended for specific markets, the factory value of the measurement system MS may be
1 (English speaking world)
Table 10: Factory settings
Summary of Contents for E.SYBOX MINI 3
Page 6: ......
Page 41: ......
Page 74: ...FRANÇAIS FR 71 ...
Page 109: ......
Page 144: ...NEDERLANDS NL 141 ...
Page 179: ...РУССКИЙ RU 176 ...
Page 214: ...SUOMI FI 211 ...
Page 246: ...SVENSKA SE 243 ...
Page 278: ...ROMÂNĂ RO 275 ...
Page 311: ......
Page 346: ......
Page 380: ...TÜRKÇE TR 377 ...
Page 413: ...POLSKI PL 410 ...
Page 447: ......
Page 480: ...MAGYAR HU 477 ...
Page 513: ...БЪЛГАРСКИ BG 510 ...
Page 545: ......
Page 578: ......
Page 614: ......
Page 647: ......
Page 680: ......