ENGLISH
GB
67
Insufficient
delivery
Red: off
White: on
Blue: off
1. Suction depth too high.
2. Suction pipe clogged or
diameter insufficient.
3. Impeller or hydraulic
part clogged.
1. As the suction depth increases the
hydraulic performance of the product
decreases. Check whether the suction
depth can be reduced. Use a suction
pipe with a larger diameter (but never
smaller than 1”).
2. Check the suction pipe, find the cause
of choking (obstruction, dry bend,
counterslope, …) and remove it.
3. Dismantle the system and remove the
obstructions (assistance service).
The pump
starts without
utility request.
Red: off
White: on
Blue: off
1. Leak in the system.
2. Faulty non-return
valve.
1. Check the system, find and eliminate
the leak.
2. Service the non-return valve as
described in par. 9.3.
The water
pressure
when turning
on the utility
is not imme
-
diate.
Red: off
White: on
Blue: off
Expansion vessel empty
(insufficient air pressure)
or has broken diaphragm.
Check the air pressure in the expansion
vessel. If water comes out when checking,
the vessel is broken: assistance service.
Otherwise restore the air pressure accord
-
ing to the equation par. 1.2.
When the
utility is
turned on the
flow falls to
zero before
the pump
starts
Red: off
White: on
Blue: off
Air pressure in the expan
-
sion vessel higher than the
system starting pressure.
TCalibrate the expansion vessel pressure or
configure the parameters SP and/or RP so
as to satisfy the equation par.1.2.
10 - TROUBLESHOOTING
Before starting to look for faults it is necessary to disconnect the power supply
to the pump (take the plug out of the socket).
Solving typical problemsi
Fault
LED
Probable Causes
Remedies
The pump
does not
start.
Red: off
White: off
Blue: off
No electric power.
Check whether there is voltage in the socket
and insert the plug again.
The pump
does not
start.
Red: on
White: on
Blue: off
Shaft blocked.
See paragraph 9.4 (motor shaft mainte
-
nance).
The pump
does not
start.
Red: off
White: on
Blue: off
Utility at a level higher
than the system restarting
pressure level (par. 3.2).
Increase the system restarting pressure
level by increasing SP or decreasing RP.
The pump
does not
stop.
Red: off
White: on
Blue: off
1. Leak in the system.
2. Impeller or hydraulic
part clogged.
3. Air getting into the
suction pipe.
4. Faulty flow sensor
1. Check the system, find and eliminate
the leak.
2. Dismantle the system and remove the
obstructions (assistance service).
3. Check the suction pipe, find and elimi
-
nate the cause of air getting in.
4. Contact the assistance centre.
Summary of Contents for E.SYBOX MINI 3
Page 6: ......
Page 41: ......
Page 74: ...FRANÇAIS FR 71 ...
Page 109: ......
Page 144: ...NEDERLANDS NL 141 ...
Page 179: ...РУССКИЙ RU 176 ...
Page 214: ...SUOMI FI 211 ...
Page 246: ...SVENSKA SE 243 ...
Page 278: ...ROMÂNĂ RO 275 ...
Page 311: ......
Page 346: ......
Page 380: ...TÜRKÇE TR 377 ...
Page 413: ...POLSKI PL 410 ...
Page 447: ......
Page 480: ...MAGYAR HU 477 ...
Page 513: ...БЪЛГАРСКИ BG 510 ...
Page 545: ......
Page 578: ......
Page 614: ......
Page 647: ......
Page 680: ......