ENGLISH
GB
42
(par. 5.5.1) in bar
So, by the manufacturer: Pair = 3.0 – 0.3 – 0.7 = 2.0 bar
If different values are set for the parameters SP and/or RP, regulate the valve of the ex
-
pansion vessel releasing or letting in air until the above equation is satisfied again (e.g.:
SP=2.0bar; RP=0.3bar; release air from the expansion vessel until a pressure of 1.0 bar
is reached on the valve).
Failure to respect the above equation may lead to malfunctions of the system
or to premature breakage of the diaphragm inside the expansion vessel.
Considering the expansion vessel capacity of only 1 litres, any operation to
check the air pressure must be performed by connecting the pressure gauge
very rapidly: on small volumes the loss of even a limited quantity of air can
cause an appreciable drop in pressure. The quality of the expansion vessel
ensures the maintenance of the set air pressure value, proceed to check it only
at calibration or if you are sure of a malfunction.
Any operation to check and/or reset the air pressure must be performed with
the delivery system not under pressure: disconnect the pump from the power
supply and open the utility nearest to the pump, keeping it open until it no
longer gives any water.
The special structure of the expansion vessel ensures its quantity and duration
over time, especially of the diaphragm which is typically the component subject
to wear for items of this type. However, in the case of breakage, the entire
expansion vessel must be replaced and exclusively by authorised personnel.
1.3 Technical characteristics
Topic
Parameter
e.sybox mini
³
ELECTRIC
POWER SUPPLY
Voltage*
1x220-240 V
1x230 V
1x110-
127 V
Frequency
50/60 Hz
Maximum power
850 W
Leakage current to earth
<2 mA
STRUCTURAL
CHARACTERISTICS
Overall dimensions
445x262x242 mm without feet support
Empty weight
(excluding packaging)
14 kg / 30,8 lb
Protection class
IP x4
Insulation class of the
motor
F
HYDRAULIC
PERFORMANCE
Maximum head
55 m / 180 ft
Maximum flow rate
80 l/min / 21 U.S. GPM
Priming
<5min at 8m / 26 ft
Maximum working
pressure
7.5 bar / 109 psi
WORKING
CONDITIONS
Max liquid temperature
40 °C / 104 °F
Max environment
temperature
50 °C / 122 °F
Environment temperature
of storage
-10÷60 °C / 14÷140 °F
Difference Ambient T. -
Liquid T.
< 30 °C / 86 °F
Max. relative humidity
50%
FUNCTIONALITY AND
PROTECTIONS
Constant pressure
Protection against dry running
Antifreeze protection
Anticycling protection
Motor overload protection
Protection against abnormal supply voltages
Protection against excess temperature
*: refer to the technical plate on the pump
2- INSTALLATION
Summary of Contents for E.SYBOX MINI 3
Page 6: ......
Page 41: ......
Page 74: ...FRANÇAIS FR 71 ...
Page 109: ......
Page 144: ...NEDERLANDS NL 141 ...
Page 179: ...РУССКИЙ RU 176 ...
Page 214: ...SUOMI FI 211 ...
Page 246: ...SVENSKA SE 243 ...