![D-Link DAS-3636 Cli Reference Manual Download Page 432](http://html.mh-extra.com/html/d-link/das-3636/das-3636_cli-reference-manual_77836432.webp)
DAS-3600 Series Ethernet over VDSL Switch CLI Reference Manual
config vdsl profile DPBOValues
Purpose
Used to config vdsl profile DPBO value.
Syntax
config vdsl profile [<profile_id 1-60>|name <profile_name 32>] DPBOValues [DPBOESEL
<int 0-511>|DPBOESCMA <int 0-640>|DPBOESCMB
<int 0-640>|DPBOESCMC <int 0-640>|DPBOMUS <int 0-255> |DPBOFMIN
<int 0-2048>|DPBOFMAX <int 32-6956> | DPBOEPSD [numpsd <int 0-32>
{frq <frq> psd_value <psd_value>} {frq <frq> psd_value <psd_value>}
{frq <frq> psd_value <psd_value>}{frq <frq> psd_value <psd_value>}
{frq <frq> psd_value <psd_value>} {frq <frq> psd_value <psd_value>}
{frq <frq> psd_value <psd_value>} {frq <frq> psd_value <psd_value>}
{frq <frq> psd_value <psd_value>}{frq <frq> psd_value <psd_value>}
{frq <frq> psd_value <psd_value>} {frq <frq> psd_value <psd_value>}
{frq <frq> psd_value <psd_value>} {frq <frq> psd_value <psd_value>}
{frq <frq> psd_value <psd_value>}{frq <frq> psd_value <psd_value>}
{frq <frq> psd_value <psd_value>} {frq <frq> psd_value <psd_value>}
{frq <frq> psd_value <psd_value>} {frq <frq> psd_value <psd_value>}
{frq <frq> psd_value <psd_value>}{frq <frq> psd_value <psd_value>}
{frq <frq> psd_value <psd_value>} {frq <frq> psd_value <psd_value>}
{frq <frq> psd_value <psd_value>} {frq <frq> psd_value <psd_value>}
{frq <frq> psd_value <psd_value>}{frq <frq> psd_value <psd_value>}
{frq <frq> psd_value <psd_value>} {frq <frq> psd_value <psd_value>}
{frq <frq> psd_value <psd_value>} {frq <frq> psd_value <psd_value>}]]
Description
This command is used to config VDSL DPBO value .
Parameters
<profile_id 1-60>–
The profile ID of the profile to be configed
name <profile_name 32>–
The name of the profile to be configed
DPBOValues
–
config DPBO(Downstream Power Back-Off) value
DPBOESEL–
Downstream Power Back-Off E-side Electrical Length
DPBOESCMA
–Downstream Power Back-Off E-side Cable Model A
DPBOESCMB–
Downstream Power Back-Off E-side Cable Model B
DPBOESCMC–
Downstream Power Back-Off E-side Cable Model C
DPBOMUS–
Downstream Power Back-Off Minimum Usable Signal
DPBOFMIN–
Downstream Power Back-Off span Minimum Frequency
DPBOFMAX–
Downstream Power Back-Off span maximum frequency
DPBOEPSD–
Downstream Power Back-Off assumed Exchange PSD mask
Restrictions
Only Administrator-level users can issue this command.
Example usage:
To config vdsl DPBO value
DAS-3626:admin#config vdsl profile name default DPBOValues DPBOESEL 30
Command: config vdsl profile name default DPBOValues DPBOESEL 30
Success.
DAS-3626:admin#
427
Summary of Contents for DAS-3636
Page 1: ...CLI Reference Manual Product Model DAS 3636 VDSL2 Switch Release 1 00 ...
Page 5: ...PASSWORD RECOVERY PROCEDURE 474 ...
Page 20: ...DAS 3600 Series Ethernet over VDSL Switch CLI Reference Manual 15 ...
Page 25: ...DAS 3600 Series Ethernet over VDSL Switch CLI Reference Manual 20 ...
Page 79: ...DAS 3600 Series Ethernet over VDSL Switch CLI Reference Manual 74 ...
Page 99: ...DAS 3600 Series Ethernet over VDSL Switch CLI Reference Manual 94 ...
Page 106: ...DAS 3600 Series Ethernet over VDSL Switch CLI Reference Manual 101 ...
Page 113: ...DAS 3600 Series Ethernet over VDSL Switch CLI Reference Manual 108 ...
Page 135: ...DAS 3600 Series Ethernet over VDSL Switch CLI Reference Manual 130 ...
Page 140: ...DAS 3600 Series Ethernet over VDSL Switch CLI Reference Manual 135 ...
Page 223: ...DAS 3600 Series Ethernet over VDSL Switch CLI Reference Manual 218 ...
Page 230: ...DAS 3600 Series Ethernet over VDSL Switch CLI Reference Manual 225 ...
Page 235: ...DAS 3600 Series Ethernet over VDSL Switch CLI Reference Manual 230 ...
Page 240: ...DAS 3600 Series Ethernet over VDSL Switch CLI Reference Manual 235 ...
Page 245: ...DAS 3600 Series Ethernet over VDSL Switch CLI Reference Manual 240 ...
Page 316: ...DAS 3600 Series Ethernet over VDSL Switch CLI Reference Manual 311 ...
Page 321: ...DAS 3600 Series Ethernet over VDSL Switch CLI Reference Manual 316 ...
Page 341: ...DAS 3600 Series Ethernet over VDSL Switch CLI Reference Manual 336 ...
Page 346: ...DAS 3600 Series Ethernet over VDSL Switch CLI Reference Manual 341 ...
Page 351: ...DAS 3600 Series Ethernet over VDSL Switch CLI Reference Manual 346 ...
Page 356: ...DAS 3600 Series Ethernet over VDSL Switch CLI Reference Manual 351 ...
Page 360: ...DAS 3600 Series Ethernet over VDSL Switch CLI Reference Manual 355 ...
Page 365: ...DAS 3600 Series Ethernet over VDSL Switch CLI Reference Manual 360 ...
Page 372: ...DAS 3600 Series Ethernet over VDSL Switch CLI Reference Manual 367 ...
Page 389: ...DAS 3600 Series Ethernet over VDSL Switch CLI Reference Manual 384 ...
Page 394: ...DAS 3600 Series Ethernet over VDSL Switch CLI Reference Manual 389 ...
Page 396: ...DAS 3600 Series Ethernet over VDSL Switch CLI Reference Manual 391 ...
Page 450: ...DAS 3600 Series Ethernet over VDSL Switch CLI Reference Manual 445 ...