52
EXPERT 64+, rev.12
EXPERT 64+
Light
Intensity
Peak
Intensity
Intensity
0%
Start Time
Sunrise
Stop Time
Sunset
Peak Cycle
CYCLE 1
CYCLE 1
CYCLE 2 CYCLE 3 CYCLE 4 CYCLE 5 CYCLE 6
LIGHT PROGRAM
Peak
Sunrise
Peak
Sunset
Duration
Time
Light Cycles
1. Select
»
7. Light Settings
»
x. Select a light program*
This menu is accessible if light programs are enabled
(sec. 4.4).
Light Settings
Exit: Press Back
Change: Press Modify
Press
to select an item
Day
24
days
Lights on 24 hours?
No
Minimum intensity
20 %
Sunrise
2 min
Sunset
2 min
Number of cycles
1
Display Settings
Cycle 1
Start Time
12:00A
Stop Time
12:00A
Standard Intensity
80 %
Use light peaks?
Yes
Peak Cycle
0:15 (h:m)
Peak Duration
1 min
Peak Intensity
100 %
Peak Sunrise
2 min
Peak Sunset
2 min
2. Set the following parameters:
Day —
This is the day at which the selected
program starts. It can be set from -5 to 450
days. Negative day values are used to prepare
the house before letting the animals enter
the building.
Lights on 24 Hours —
Select
“Yes”
for lights
to stay lit all day long; select
“No”
to use
light cycles.
Maximum Intensity —
If the “lights on 24
hours” option is enabled above, set the
maximum light intensity to the desired value.
*
Accessible if the “Lights on 24 hours” option is
enabled above.
Minimum Intensity —
Set the light intensity
that is used when light cycles are off. Adjust-
able from 0% (Off) to 100%. *
Accessible if the
“lights on 24 hours” option is disabled above.
Summary of Contents for EXPERT 64 Plus