10
EXPERT 64+, rev.12
EXPERT 64+
LCD Display
Arrow keys
LED Display
Status LEDs
3.2. How to Select & Modify
the Parameters
1. Use the arrow keys to select the desired
parameter. The message
“Change : Press
Modify”
is shown at the bottom of the display.
This means that the selected parameter can
be edited.
2. Press the
“Enter/Modify”
button to access
3.3. Status LEDs
LED
MEANING
ALARM
Turns on when an alarm is active.
Flashes when an alarm condition occurred and was re-established by itself.
CLOCKS
Turns on when a clock output is active
LIGHTS
Turns on when the light output is active
VENT
DOORS
OPEN
Turns on when a vent door is opening (sidewall and/or attic vent)
CLOSE
Turns on when a vent door is closing (sidewall and/or attic vent)
TUNNEL
CUR-
TAIN
OPEN
Turns on when the tunnel curtain is opening
CLOSE
Turns on when the tunnel curtain is closing
COOL-
ING
2
Turns on when cooling output 4, 5 or 6 is active
1
Turns on when cooling output 1,2 or 3 is active
TUNNEL FANS 1-16
Turns on when tunnel fan group 1-16 is active
FANS 1-16
Turns on when fan group 1-16 is active
HEATERS 1-8
Flashes when one step of the heating output is operating (regular or high fire
step). Turns on when both steps of the heating output are operating (regular
and high fire steps).
the editing mode. The parameter then flashes
on the display.
3. Use the up and down-arrow keys to
change the value of the parameter.
4. Press the
“Enter/Modify”
button once
again to validate the new value and to exit
the editing mode.
Summary of Contents for EXPERT 64 Plus
Page 1: ...EXPERT 64 Temperature Controller User s manual...
Page 62: ......